Physiological axial compressive preloads increase motion segment stiffness, linearity and hysteresis in all six degrees of freedom for small displacements about the neutral posture
- 1 May 2003
- journal article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 21 (3), 547-552
- https://doi.org/10.1016/s0736-0266(02)00199-7
Abstract
The stiffness of motion segments, together with muscle actions, stabilizes the spinal column. The objective of this study was to compare the experimentally measured load-displacement behavior of porcine lumbar motion segments in vitro with physiological axial compressive preloads of 0, 200 and 400 N equilibrated in a physiological fluid environment, for small displacements about the neutral posture. These preloads are hypothesized to increase stiffness, hysteresis and linearity of the load-displacement behavior. At each preload, displacements in each of six degrees of freedom (+/-0.3 mm AP and lateral translations, +/-0.2 mm axial translation, +/-1 degrees lateral bending and +/-0.8 degrees flexion/extension and torsional rotations) were imposed. The resulting forces and moments were recorded. Tests were repeated after removal of posterior elements. Using least squares, the forces at the vertebral body center were related to the displacements by a symmetric 6 x 6 stiffness matrix. Six diagonal and two off-diagonal load-displacement relationships were examined for differences in stiffness, linearity and hysteresis in each testing condition. Mean values of the diagonal terms of the stiffness matrix for intact porcine motion segments increased significantly by an average factor of 2.2 and 2.9 with 200 and 400 N axial compression respectively (p<0.001). Increases for isolated disc specimens averaged 4.6 and 6.9 times with 200 and 400 N preload (p<0.001). Changes in hysteresis correlated with the changes in stiffness. The load-displacement relationships were progressively more linear with increasing preload (R(2)=0.82, 0.97 and 0.98 at 0, 200 and 400 N axial compression respectively). Motion segment and disc load-displacement behaviors were stiffer, more linear and had greater hysteresis with axial compressive preloads.Keywords
This publication has 18 references indexed in Scilit:
- Effect of Test Environment on Intervertebral Disc HydrationSpine, 1997
- Role of muscles in lumbar spine stability in maximum extension effortsJournal of Orthopaedic Research, 1995
- Biomechanical risk factors for occupationally related low back disordersErgonomics, 1995
- Stability Increase of the Lumbar Spine With Different Muscle GroupsSpine, 1995
- Large compressive preloads decrease lumbar motion segment flexibilityJournal of Orthopaedic Research, 1991
- Water Diffusion Pathway, Swelling Pressure, and Biomechanical Properties of the Intervertebral Disc During Compression LoadSpine, 1989
- Stability of the lumbar spineActa Orthopaedica, 1989
- Three-Dimensional Motion Behavior of the Human Spine—A Question of TerminologyJournal of Biomechanical Engineering, 1987
- On the Mechanical Behaviour of Intervertebral DiscsSpine, 1983
- Derivation of a new stiffness matrix for helically armoured cables considering tension and torsionInternational Journal for Numerical Methods in Engineering, 1979