Unrestrained video-assisted plethysmography: a noninvasive method for assessment of lung mechanical function in small animals
Open Access
- 1 January 2008
- journal article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 104 (1), 253-261
- https://doi.org/10.1152/japplphysiol.00737.2007
Abstract
The assessment of lung mechanical function in small animals, particularly mice, is essential for investigations into the pathophysiology of pulmonary disease. The most accurate and specific methods for making this assessment are highly invasive and so provide data of questionable relevance to normality. By contrast, present noninvasive methods based on unrestrained plethysmography have no direct link to the mechanical properties of the lung. There is thus a need for a completely noninvasive method for determining lung mechanical function in small animals. In the present study, we demonstrate an extension of unrestrained plethysmography in which changes in lung volume are estimated via orthogonal video imaging of the thorax. These estimates are combined with the pressure swings recorded as mice breathe inside a heated and humidified chamber to yield an estimate of specific airway resistance (sRaw). We used this new technique, which we term “unrestrained video-assisted plethysmography” (UVAP), to measure sRaw in 11 BALB/c mice exposed to aerosols of saline, methacholine, and albuterol and obtained mean values of 0.71, 1.23 and 1.10 cmH2O·s, respectively. Mean breathing frequency was 4.3, 3.4, and 3.6 breaths/s, respectively, while the corresponding mean tidal volumes were 0.36, 0.44 and 0.37 ml, respectively. We conclude that UVAP, a noninvasive method, is able to provide usefully accurate estimates of sRaw and breathing pattern parameters in mice.Keywords
This publication has 23 references indexed in Scilit:
- End-expiratory and tidal volumes measured in conscious mice using single projection x-ray imagesJournal of Applied Physiology, 2008
- Exaggerated airway narrowing in mice treated with intratracheal cationic proteinJournal of Applied Physiology, 2006
- Unrestrained plethysmography is an unreliable measure of airway responsiveness in BALB/c and C57BL/6 miceJournal of Applied Physiology, 2004
- The "Goldilocks Effect" in Cystic Fibrosis: identification of a lung phenotype in the cftr knockout and heterozygous mouseBMC Genomic Data, 2004
- Measuring lung function in mice: the phenotyping uncertainty principleJournal of Applied Physiology, 2003
- Compartmental Analysis of Breathing in the Supine and Prone Positions by Optoelectronic PlethysmographyAnnals of Biomedical Engineering, 2001
- Noninvasive Measurement of Airway Responsiveness in Allergic Mice Using Barometric PlethysmographyAmerican Journal of Respiratory and Critical Care Medicine, 1997
- Quantification of nasal involvement in a guinea pig plethysmographJournal of Applied Physiology, 1994
- Input impedance and peripheral inhomogeneity of dog lungsJournal of Applied Physiology, 1992
- Partitioning of airway responses to inhaled methacholine in the ratJournal of Applied Physiology, 1987