Manipulation of image intensity distribution at 7.0 T: Passive RF shimming and focusing with dielectric materials
Open Access
- 5 June 2006
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 24 (1), 197-202
- https://doi.org/10.1002/jmri.20603
Abstract
Purpose To investigate the effects of high dielectric material padding on RF field distribution in the human head at 7.0 T, and demonstrate the feasibility and effectiveness of RF passive shimming and focusing with such an approach. Materials and Methods The intensity distribution changes of gradient-recalled-echo (GRE) and spin-echo (SE) images of a human head acquired with water pads (dielectric constant = 78) placed in specified configurations around the head at 7.0 T were evaluated and compared with computer simulation results using the finite difference time domain (FDTD) method. The contributions to the B1 field distribution change from the displacement current and conductive current of a given configuration of dielectric padding were determined with computer simulations. Results MR image intensity distribution in the human head with an RF coil at 7.0 T can be changed drastically by placing water pads around the head. Computer simulations reveal that the high permittivity of water pads results in a strong displacement current that enhances image intensity in the nearby region and alters the intensity distribution of the entire brain. Conclusion The image intensity distribution in the human head at ultra-high field strengths can be effectively manipulated with high permittivity padding. Utilizing this effect, the B1 field inside the human head of a given RF coil can be adjusted to reduce the B1 field inhomogeneity artifact associated with the wave behavior (RF passive shimming) or to locally enhance the signal-to-noise ratio (SNR) in targeted regions of interest (ROIs; RF field focusing). J. Magn. Reson. Imaging 2006.Keywords
This publication has 23 references indexed in Scilit:
- Central brightening due to constructive interference with, without, and despite dielectric resonanceJournal of Magnetic Resonance Imaging, 2005
- Polarization of the RF field in a human head at high field: A study with a quadrature surface coil at 7.0 TMagnetic Resonance in Medicine, 2002
- Analysis of wave behavior in lossy dielectric samples at high fieldMagnetic Resonance in Medicine, 2002
- Different excitation and reception distributions with a single‐loop transmit‐receive surface coil near a head‐sized spherical phantom at 300 MHzMagnetic Resonance in Medicine, 2002
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Standing-wave and RF penetration artifacts caused by elliptic geometry: an electrodynamic analysis of MRIIEEE Transactions on Medical Imaging, 1998
- High frequency volume coils for clinical NMR imaging and spectroscopyMagnetic Resonance in Medicine, 1994
- Reduction of RF penetration effects in high field imagingMagnetic Resonance in Medicine, 1992
- Spectroscopy and imaging with a 4 tesla whole‐body mr systemNMR in Biomedicine, 1988
- Comparison of linear and circular polarization for magnetic resonance imagingJournal of Magnetic Resonance (1969), 1985