Combining Functional and Structural Tests Improves the Diagnostic Accuracy of Relevance Vector Machine Classifiers
Open Access
- 1 March 2010
- journal article
- research article
- Published by Ovid Technologies (Wolters Kluwer Health) in Journal of Glaucoma
- Vol. 19 (3), 167-175
- https://doi.org/10.1097/ijg.0b013e3181a98b85
Abstract
Purpose To investigate whether combining optic disc topography and short-wavelength automated perimetry (SWAP) data improves the diagnostic accuracy of relevance vector machine (RVM) classifiers for detecting glaucomatous eyes compared with using each test alone. Methods One eye of 144 glaucoma patients and 68 healthy controls from the Diagnostic Innovations in Glaucoma Study were included. RVM were trained and tested with cross-validation on optimized (backward elimination) SWAP features (thresholds plus age; pattern deviation; and total deviation) and on Heidelberg retina tomograph II (HRT) optic disc topography features, independently and in combination. RVM performance was also compared with 2 HRT linear discriminant functions and to SWAP mean deviation and pattern standard deviation. Classifier performance was measured by the area under the receiver operating characteristic curves (AUROCs) generated for each feature set and by the sensitivities at set specificities of 75%, 90%, and 96%. Results RVM trained on combined HRT and SWAP thresholds plus age had significantly higher AUROC (0.93) than RVM trained on HRT (0.88) and SWAP (0.76) alone. AUROCs for the SWAP global indices (mean deviation: 0.68; pattern standard deviation: 0.72) offered no advantage over SWAP thresholds plus age, whereas the linear discriminant functions AUROCs were significantly lower than RVM trained on the combined SWAP and HRT feature set and on HRT alone feature set. Conclusions Training RVM on combined optimized HRT and SWAP data improved diagnostic accuracy compared with training on SWAP and HRT parameters alone. Future research may identify other combinations of tests and classifiers that can also improve diagnostic accuracy.Keywords
This publication has 36 references indexed in Scilit:
- Comparing the Full-Threshold and Swedish Interactive Thresholding Algorithms for Short-Wavelength Automated PerimetryInvestigative Ophthalmology & Visual Science, 2009
- The Impact of the Perimetric Measurement Scale, Sample Composition, and Statistical Method on the Structure-function Relationship in GlaucomaJournal of Glaucoma, 2007
- Identifying Glaucomatous Vision Loss with Visual-Function–Specific Perimetry in the Diagnostic Innovations in Glaucoma StudyInvestigative Ophthalmology & Visual Science, 2006
- Improving Glaucoma Diagnosis by the Combination of Perimetry and HRT MeasurementsJournal of Glaucoma, 2006
- Factors affecting the test-retest variability of Heidelberg retina tomograph and Heidelberg retina tomograph II measurementsBritish Journal of Ophthalmology, 2005
- Relevance vector machine and support vector machine classifier analysis of scanning laser polarimetry retinal nerve fiber layer measurements.Investigative Ophthalmology & Visual Science, 2005
- Results of the European Glaucoma Prevention StudyOphthalmology, 2005
- Short-wavelength automated perimetryOphthalmology Clinics of North America, 2003
- Identification of early glaucoma cases with the scanning laser ophthalmoscopeOphthalmology, 1998