Preliminary investigation of the NMR, optical and x-ray CT dose–response of polymer gel dosimeters incorporating cosolvents to improve dose sensitivity
- 15 April 2009
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (9), 2779-2790
- https://doi.org/10.1088/0031-9155/54/9/013
Abstract
This study reports on efforts to increase the dose sensitivity of polymer gel dosimeters used in 3D radiation dosimetry. The potential of several different cosolvents is investigated, with the aim of increasing the solubility of N,N'-methylene-bisacrylamide crosslinker in polymer gel dosimeters. Glycerol and isopropanol increase the limit for the crosslinker solubility from approximately 3% to 5% and 10% by weight, respectively. This enables the manufacture of polymer gel dosimeters with much higher levels of crosslinking than was previously possible. New dosimeter recipes containing up to 5 wt% N,N'-methylene-bisacrylamide were subjected to spatially uniform radiation and were studied using nuclear magnetic resonance (NMR), as well as x-ray and optical CT techniques. The resulting dosimeters exhibit dose sensitivities that are up to 2.7 times higher than measured for a typical dosimeters with 3% N,N'-methylene-bisacrylamide without the addition of cosolvent. Two additional cosolvents (n-propanol and sec-butanol) were deemed unsuitable for practical dosimeters due to incompatibility with gelatin, cloudiness prior to irradiation, and immiscibility with water when large quantities of cosolvent were used. The dosimeters with high N,N'-methylene-bisacrylamide content that used isopropanol or glycerol as cosolvents had high optical clarity prior to irradiation, but did not produce suitable optical CT results for non-uniformly irradiated gels due to polymer development outside of the high dose regions of the pencil beams and significant light scatter. Further experiments are required to determine whether cosolvents can be used to manufacture gels with sufficiently high dose sensitivity for readout using x-ray computed tomography.This publication has 23 references indexed in Scilit:
- Effects of glycerol co-solvent on the rate and form of polymer gel dose responsePhysics in Medicine & Biology, 2009
- Initial experience with a commercial cone beam optical CT unit for polymer gel dosimetry I: Optical dosimetry issuesJournal of Physics: Conference Series, 2006
- Initial experience with a commercial cone beam optical CT unit for polymer gel dosimetry II: Clinical potentialJournal of Physics: Conference Series, 2006
- An NMR relaxometry and gravimetric study of gelatin-free aqueous polyacrylamide dosimetersPhysics in Medicine & Biology, 2006
- The fundamental radiation properties of normoxic polymer gel dosimeters: a comparison between a methacrylic acid based gel and acrylamide based gelsPhysics in Medicine & Biology, 2006
- Applications of gel dosimetryJournal of Physics: Conference Series, 2004
- A basic study of some normoxic polymer gel dosimetersPhysics in Medicine & Biology, 2002
- Polymer gel dosimetry using x-ray computed tomography: a feasibility study4Physics in Medicine & Biology, 2000
- Experimental procedure for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI) radiation dosimetryPhysics in Medicine & Biology, 1998
- Kinetics of polymerization of N,N-methylenebisacrylamide initiated by KMnO4-H2C2O4 redox systemEuropean Polymer Journal, 1982