Sonication improved the diagnosis of orthopedic implant-associated infections (OIAI). We investigated the diagnostic performance of sonication fluid inoculated into blood culture bottles in comparison with that of intraoperative tissue and sonication fluid cultures. Consecutive patients with removed orthopedic hardware were prospectively included and classified as having OIAI or aseptic failure (AF) according to standardized criteria. The diagnostic procedure included the collection of five intraoperative tissue cultures and sonication of the removed device, followed by conventional culture of the sonication fluid. Cultures were incubated for 7 days (aerobic) or 14 days (anaerobic). In addition, 10 ml of sonication fluid was inoculated into each aerobic and anaerobic BacT/Alert FAN blood culture bottle and incubated in the automated blood culture system for 5 days. Of 75 included patients, 39 had OIAI and 36 AF. The sensitivity of sonication fluid inoculated into blood culture bottles (100%) was higher than that of conventional sonication fluid (87%; P = 0.05) or intraoperative tissue cultures (59%; P < 0.01). Previous antibiotic therapy reduced the culture sensitivity of conventional sonication fluid to 77% and that of intraoperative tissue to 55%, while it remained 100% for blood culture-inoculated sonication fluid. The time to positivity was shorter in blood culture-inoculated sonication fluid, with detection of 72% of microorganisms after 1 day of incubation, than for intraoperative tissue and conventional sonication fluid cultures, with detection of 18% and 28% of microorganisms, respectively. In conclusion, compared to conventional sonication fluid and intraoperative tissue cultures, sonication fluid inoculated into blood culture bottles improved the diagnosis of OIAI and considerably reduced the time to culture positivity.Keywords
This publication has 29 references indexed in Scilit:
- Propionibacterium acnes: An Underestimated Pathogen in Implant-Associated InfectionsBioMed Research International, 2013
- Prosthetic Joint Infection Diagnosis Using Broad-Range PCR of Biofilms Dislodged from Knee and Hip Arthroplasty Surfaces Using SonicationJournal of Clinical Microbiology, 2012
- Sonication cultures of explanted components as an add‐on test to routinely conducted microbiological diagnostics improve pathogen detectionJournal of Orthopaedic Research, 2010
- Bacterial Colonization and Infection of Electrophysiological Cardiac Devices Detected With Sonication and Swab CultureCirculation, 2010
- Improved Diagnosis of Periprosthetic Joint Infection by Multiplex PCR of Sonication Fluid from Removed ImplantsJournal of Clinical Microbiology, 2010
- In Vitro Effect of Ultrasound on Bacteria and Suggested Protocol for Sonication and Diagnosis of Prosthetic InfectionsJournal of Clinical Microbiology, 2009
- Microbiologic Diagnosis of Prosthetic Shoulder Infection by Use of Implant SonicationJournal of Clinical Microbiology, 2009
- Culture-Negative Prosthetic Joint InfectionClinical Infectious Diseases, 2007
- Sonication of Removed Hip and Knee Prostheses for Diagnosis of InfectionThe New England Journal of Medicine, 2007
- Culture with BACTEC Peds Plus/F Bottle Compared with Conventional Methods for Detection of Bacteria in Synovial FluidJournal of Clinical Microbiology, 2001