Cooking fuel type, household ventilation, and the risk of acute lower respiratory illness in urban Bangladeshi children: a longitudinal study
- 18 October 2011
- journal article
- Published by Hindawi Limited in Indoor Air
- Vol. 22 (2), 132-139
- https://doi.org/10.1111/j.1600-0668.2011.00754.x
Abstract
Acute lower respiratory illnesses (ALRI) are the leading cause of death among children <5 years. Studies have found that biomass cooking fuels are an important risk factor for ALRI. However, few studies have evaluated the influence of natural household ventilation indicators on ALRI. The purpose of this study was to assess the association between cooking fuel, natural household ventilation, and ALRI. During October 17, 2004–September 30, 2005, children <5 years living in a low‐income neighborhood of Dhaka, Bangladesh, were assessed weekly for ALRI and surveyed quarterly about biomass fuel use, electric fan ownership, and natural household ventilation (windows, ventilation grates, and presence of a gap between the wall and ceiling). Bivariate and multivariate analyses were performed using generalized estimating equations. Six thousand and seventy‐nine children <5 years enrolled during the study period (99% participation) experienced 1291 ALRI. In the multivariate model, ≥2 windows [OR = 0.75, 95% CI = (0.58, 0.96)], ventilation grates [OR = 0.80, 95% CI = (0.65, 0.98)], and not owning an electric fan [OR = 1.50, 95% CI = (1.21, 1.88)] were associated with ALRI; gap presence and using biomass fuels were not associated with ALRI. Structural factors that might improve household air circulation and exchange were associated with decreased ALRI risk. Improved natural ventilation might reduce ALRI among children in low‐income families. Practical Implications The World Health Organization has stated that controlling pneumonia is a priority for achieving the fourth Millennium Development Goal, which calls for a two‐third reduction in mortality of children <5 years old compared to the 1990 baseline. Our study represents an important finding of a modifiable risk factor that might decrease the burden of respiratory illness among children living in Bangladesh and other low‐income settings similar to our study site. We found that the existence of at least two windows in the child’s sleeping room was associated with a 25% decreased ALRI risk. Increasing available natural ventilation within the household in similar settings has the potential to reduce childhood mortality because of acute lower respiratory illnesses.Keywords
This publication has 15 references indexed in Scilit:
- The value of vaccinationPublished by Informa UK Limited ,2017
- Distribution of Airborne Influenza Virus and Respiratory Syncytial Virus in an Urgent Care Medical ClinicClinical Infectious Diseases, 2010
- Efficacy of Soap and Water and Alcohol‐Based Hand‐Rub Preparations against Live H1N1 Influenza Virus on the Hands of Human VolunteersClinical Infectious Diseases, 2009
- Role of ventilation in airborne transmission of infectious agents in the built environment ? a multidisciplinary systematic reviewIndoor Air, 2007
- Indoor air quality for poor families: new evidence from BangladeshIndoor Air, 2006
- Effect of weekly zinc supplements on incidence of pneumonia and diarrhoea in children younger than 2 years in an urban, low-income population in Bangladesh: randomised controlled trialThe Lancet, 2005
- Relationship between environmental tobacco smoke and urinary cotinine levels in passive smokers at their residenceJournal of Exposure Science & Environmental Epidemiology, 2004
- Exposure assessment for respirable particulates associated with household fuel use in rural districts of Andhra Pradesh, IndiaJournal of Exposure Science & Environmental Epidemiology, 2004
- Respiratory diseases in children and outdoor air pollution in Sao Paulo, Brazil: a time series analysisOccupational and Environmental Medicine, 2000
- Epidemiology of Acute Respiratory Tract Infections Among Guatemalan Ambulatory Preschool CbildrenClinical Infectious Diseases, 1990