Validation of the fetal myocardial performance index in the second and third trimesters of gestation
Open Access
- 30 October 2008
- journal article
- research article
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 33 (1), 58-63
- https://doi.org/10.1002/uog.6238
Abstract
Objectives To test the validity of the myocardial performance index (MPI) and its components against the more conventional methods of fetal cardiac function assessment: the ejection fraction (EF) for systolic function and the E/A index (ratio of transmitral flow during early (E) ventricular filling to flow during atrial (A) contraction) for diastolic function, both in a normal population and in a population at risk for cardiac failure because of volume overload (recipient fetuses in cases of twin–twin transfusion syndrome (TTTS)). Methods The MPI was measured prospectively in addition to more commonly used indices of systolic (EF) and diastolic (E/A index) cardiac function in 117 healthy fetuses (gestational age range, 20–36 weeks) and in 14 fetuses suspected of cardiac failure because of the presence of TTTS. Nomograms were constructed for all variables, and correlations between the MPI, EF and E/A index were assessed. The time taken to obtain the measurements as well as the interobserver and intraobserver variability were determined for the MPI and EF. Results In healthy fetuses, the MPI and EF were independent of gestational age, whereas the E/A index and isovolumetric relaxation time (IRT) increased with gestational age. The MPI correlated inversely with the EF (P < 0.001). The IRT showed a trend towards an inverse correlation with the E/A index (P = 0.10). The mean ± SD time needed to measure the MPI and EF was 140 ± 65 s and 185 ± 187 s, respectively (P = 0.43). Interobserver and intraobserver intraclass correlation coefficients for the MPI were 0.98 (95% CI, 0.85–0.99) and 0.82 (95% CI, 0.14–0.95), respectively; those for the EF were 0.58 (95% CI, − 0.16 to 0.85) and 0.51 (95% CI, − 0.46 to 0.83), respectively; and those for the E/A index were 0.97 (95% CI, 0.88–0.99) and 0.91 (95% CI, 0.66–0.98), respectively. All variables, except ejection time, were significantly different between normal fetuses and those with TTTS. Conclusions The MPI is an indicator of the systolic component of fetal left ventricular function that can be easily acquired and reproduced. The MPI is strongly correlated with the EF but shows less interobserver and intraobserver variability. Copyright © 2008 ISUOG. Published by John Wiley & Sons, Ltd.Keywords
This publication has 19 references indexed in Scilit:
- Early manifestations and spectrum of recipient twin cardiomyopathy in twin–twin transfusion syndrome: relation to Quintero stageUltrasound in Obstetrics & Gynecology, 2007
- Estimation of fetal weight: reference range at 20–36 weeks' gestation and comparison with actual birth‐weight reference rangeUltrasound in Obstetrics & Gynecology, 2007
- Assessment of Fetal Myocardial Performance Using Myocardial Deformation AnalysisThe American Journal of Cardiology, 2007
- Correlation of Tei Index Obtained from Tissue Doppler Echocardiography with Invasive Measurements of Left Ventricular PerformanceEchocardiography, 2007
- Gestational‐age‐adjusted reference values for the modified myocardial performance index for evaluation of fetal left cardiac functionUltrasound in Obstetrics & Gynecology, 2007
- Assessing fetal cardiac ventricular functionSeminars in Fetal and Neonatal Medicine, 2005
- Measuring left ventricular myocardial performance index in fetusesThe American Journal of Cardiology, 2003
- Fetal cardiac function assessed by Doppler myocardial performance index (Tei Index)Ultrasound in Obstetrics & Gynecology, 2003
- Longitudinal survey of fetal ventricular ejection and shortening fraction throughout pregnancyUltrasound in Obstetrics & Gynecology, 2000
- Noninvasive Doppler-derived myocardial performance index: Correlation with simultaneous measurements of cardiac catheterization measurementsJournal of the American Society of Echocardiography, 1997