The effect of ergometer design on rowing stroke mechanics
- 30 October 2011
- journal article
- research article
- Published by Wiley in Scandinavian Journal of Medicine & Science in Sports
- Vol. 23 (4), 468-477
- https://doi.org/10.1111/j.1600-0838.2011.01404.x
Abstract
The effect of rowing ergometer design upon power delivery and coordination patterns of the rowing stroke was analyzed for 14 elite rowers. Rowers were tested in three ergometer conditions: the fixed stretcher Concept2c ergometer, the Concept2c ergometer mounted on sliding rails, and the sliding stretcher RowPerfect ergometer. Ergometers were instrumented to measure the external force generated at the handle and the foot stretcher and a nine-segment inverse dynamics model used to calculate joint and overall power delivery. Peak power generation and absorption at the knee joint was significantly greater, and total power delivered to the ergometer delayed on the fixed stretcher ergometer when compared to the sliding stretcher ergometers. No differences were found in the mechanical energy delivered to the handle of the three ergometers; however, greater joint mechanical energy production of the lower limb reduced mechanical efficiency when rowing the Concept2c fixed ergometer. The fixed foot stretcher on the Concept2c fixed ergometer acts to increase the inertial forces that the rower must overcome at the catch, increasing the moment and power output at the knee, and affecting the coordination pattern during the recovery phase.Keywords
This publication has 24 references indexed in Scilit:
- Relative shank to thigh length is associated with different mechanisms of power production during elite male ergometer rowingSports Biomechanics, 2009
- Fixed versus free-floating stretcher mechanism in rowing ergometers: Mechanical aspectsJournal of Sports Sciences, 2006
- Towards an Ideal Rowing Technique for PerformanceSports Medicine, 2004
- An ergonomic comparison of rowing machine designs: possible implications for safetyBritish Journal of Sports Medicine, 2002
- High reliability of performance of well-trained rowers on a rowing ergometerJournal of Sports Sciences, 1999
- The Rowing Cycle: Sources of Variance and Invariance in Ergometer and On-the-Water PerformanceJournal of Motor Behavior, 1998
- Discriminant analysis of biomechanical differences between novice, good and elite rowersJournal of Sports Sciences, 1995
- A comparison of the accuracy of several hip center location prediction methodsJournal of Biomechanics, 1990
- A kinematic comparison of ergometer and on-water rowingThe American Journal of Sports Medicine, 1989
- Measurement of the trunk musculature of active males using CT scan radiography: Implications for force and moment generating capacity about the L4L5 jointJournal of Biomechanics, 1988