Abstract
In this paper, the development of a fully implantable wireless sensor able to provide continuous real-time accurate pressure measurements is presented. Surface Acoustic Wave (SAW) technology was used to deposit resonators on crystalline quartz wafers; the wafers were then assembled to produce a pressure sensitive device. Excitation and reading via a miniature antenna attached to the pressure sensor enables continuous external interrogation. The main advantages of such a configuration are the long term stability of quartz and the low power necessary for the interrogation, which allows 24/7 interrogation by means of a hand-held, battery powered device. Such data are of vital importance to clinicians monitoring and treating the effects of hypertension and heart failure. A prototype was designed and tested using both a bio-phantom test rig and an animal model. The pressure traces for both compare very well with a commercially available catheter tip pressure transducer. The work presented in this paper is the first known wireless pressure data from the left ventricle of the heart of a living swine.Keywords
This publication has 38 references indexed in Scilit:
- Development of a fully implantable wireless pressure monitoring systemBiomedical Microdevices, 2008
- Effectiveness of Home Blood Pressure Monitoring, Web Communication, and Pharmacist Care on Hypertension ControlJAMA, 2008
- Mechanical properties of silicones for MEMSJournal of Micromechanics and Microengineering, 2008
- Comparison of a Radiofrequency-Based Wireless Pressure Sensor to Swan-Ganz Catheter and Echocardiography for Ambulatory Assessment of Pulmonary Artery Pressure in Heart FailureJournal of the American College of Cardiology, 2007
- Direct Left Atrial Pressure Monitoring in Ambulatory Heart Failure PatientsCirculation, 2007
- Wireless Acoustic Communication With a Miniature Pressure Sensor in the Pulmonary Artery for Disease Surveillance and Therapy of Patients With Congestive Heart FailureJournal of the American College of Cardiology, 2007
- Expanding the Use of Ambulatory Blood Pressure Monitoring for the Diagnosis and Management of Patients With HypertensionHypertension, 2006
- Implanted Antennas Inside a Human Body: Simulations, Designs, and CharacterizationsIEEE Transactions on Microwave Theory and Techniques, 2004
- Design of Implantable Microstrip Antenna for Communication With Medical ImplantsIEEE Transactions on Microwave Theory and Techniques, 2004
- The chirp z-transform algorithmIEEE Transactions on Audio and Electroacoustics, 1969