Comparison ofp-type commercial electron diodes forin vivodosimetry
- 15 December 2003
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 31 (1), 50-56
- https://doi.org/10.1118/1.1630492
Abstract
This paper compares the characteristics of three types of commercial p-type electron diodes specially designed for in vivodosimetry (Scanditronix EDD2, Sun Nuclear QED 111200-0 and PTW T60010E diodes coupled with a Therados DPD510 dosimeter) in electron fields with energies from 4.5 to 21 MeV, and in conditions similar to those encountered in radiotherapy. In addition to the diodes, a NACP plane parallel ionization chamber and film dosimeters have been used in the experiments. The influence of beam direction on the diode responses (directional effect) was investigated. It was found to be the greatest for the lowest electron beam energy. At 12 MeV and an incidence of ±30°, the variation was found to be less than 1% for the Scanditronix and Sun Nuclear diodes and less than 3% for the PTW one. The three diodes exhibited a variation in sensitivity with dose-per-pulse of less than 1% over the range 0.18–0.43 mGy/pulse. The temperature dependence was also studied. The response was linear for the three diodes between 22.2 and 40 °C and the sensitivity variations with temperature were (0.25±0.01)%/°C, (0.28±0.01)%/°C, and (0.02±0.01)%/°C for Scanditronix, Sun Nuclear, and PTW diodes, respectively. Finally the perturbation to the irradiation field induced by the presence of diodes placed at the surface of a homogeneous phantom was investigated and found to be significant, both at the surface and at the depth of maximum dose (several tens of percent) for all three diode types. There is an increase of dose right underneath the diode (close to the surface) and a dose shadow at the depth of maximum. The study shows that electron diodes can be used for in vivodosimetry provided their characteristics are carefully established before use and taken into consideration at the time of interpretation of the results.Keywords
This publication has 16 references indexed in Scilit:
- The thermal characteristics of different diodes on in vivo patient dosimetryMedical Physics, 2001
- The routine use of personal patient dosimeters is of little value in detecting therapeutic misadministrationsMedical Physics, 2001
- A method to improve the effectiveness of diodein vivodosimetryMedical Physics, 1998
- Quantitative assessment of beam perturbations caused by silicon diodes used for in vivo dosimetryInternational Journal of Radiation Oncology*Biology*Physics, 1996
- Quality assurance in radiotherapy: the importance of medical physics staffing levels. Recommendations from an ESTRO/EFOMP joint task groupRadiotherapy and Oncology, 1996
- A model for calculating the costs of in vivo dosimetry and portal imaging in radiotherapy departmentsRadiotherapy and Oncology, 1993
- Linearity with dose rate of low resistivity p-type silicon semiconductor detectorsPhysics in Medicine & Biology, 1993
- In vivo dosimetry during pelvic treatmentRadiotherapy and Oncology, 1992
- Evaluation of temperature effects in p-type silicon detectorsPhysics in Medicine & Biology, 1986
- Calibration and use of Plane-Parallel Ionization Chambers for the Determination of Absorbed Dose in Electron BeamsActa Radiologica: Oncology, 1981