Abstract
The cooling load calculation of building envelopes is important for building design to realize building energy efficiency. A simplified way to predict the building envelope cooling loads is desperately needed to predict the cooling load of building envelopes with various construction layouts and to predict the energy-saving effect of various reconstruction measures for buildings. In light of this need a simplified calculation model for building envelope cooling loads is proposed in this paper. The model is based on dynamic hourly calculations using EnergyPlus. It considers almost all the thermal factors about the building envelope which may affect the building cooling load and it is studied by dimensional analysis. The equivalent window to wall ratio (EWWR) and building orientation factor are defined to study the building envelope cooling load. The cooling loads of twenty hypothetical buildings with various envelopes are predicated by EnergyPlus. With the results from EnergyPlus the simplified calculation model is developed by MATLAB. Then the newly developed model is validated by two typical actual buildings located in Central-South China. The results show the model is accurate enough to predict the building envelope cooling loads.Funding Information
- National Natural Science Foundation of China (51378186)
- Natural Science Foundation of Zhejiang Province (LQ14E080003)
This publication has 19 references indexed in Scilit:
- Prediction model of Cooling Load considering time-lag for preemptive action in buildingsEnergy and Buildings, 2017
- Operating optimization for improved energy consumption of a TAC system affected by nighttime thermal loads of building envelopesEnergy, 2017
- A new method for calculating conduction response factors for multilayer constructions based on frequency–Domain spline interpolation (FDSI) and asymptotic analysisEnergy and Buildings, 2017
- A short-term building cooling load prediction method using deep learning algorithmsApplied Energy, 2017
- Environmental assessment of deep energy refurbishment for energy efficiency-case study of an office building in New ZealandJournal of Affective Disorders, 2017
- Early-Stage Design Considerations for the Energy-Efficiency of High-Rise Office BuildingsSustainability, 2017
- A review of artificial intelligence based building energy use prediction: Contrasting the capabilities of single and ensemble prediction modelsRenewable and Sustainable Energy Reviews, 2016
- Estimating hourly cooling load in commercial buildings using a thermal network model and electricity submetering dataApplied Energy, 2016
- Thermodynamic investigation of building integrated energy efficiency for building retrofitEnergy and Buildings, 2014