Adsorption equilibrium in immuno‐affinity chromatography with polyclonal and monoclonal antibodies

Abstract
The effects of pH, ionic strength, anion species, and antibody concentration on the adsorption equilibrium between immobilized antibodies and antigens were studied by use of anti‐BSA, anti‐HSA, anti‐BlgG, and monoclonal anti‐HSA coupled to Sepharose 4B. The polyclonal antibodies possessed average binding affinities of the order of 108M−1, and the heterogeneity was accounted for by assuming a normal distribution of the free energy of antibody–antigen combination. The monoclonal antibody, on the other hand, showed a homogeneous affinity of the Langmuir type. Bound antigens could be eluted by lowering pH or adding a chaotropic anion, and their purity was very high. The antibody ligand was sufficiently stable for repeated use.