Multiple Amplatzer septal occluder devices for multiple atrial communications: Immediate and long‐term follow‐up results
- 16 July 2007
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 70 (2), 265-273
- https://doi.org/10.1002/ccd.21145
Abstract
Objectives: We report on the feasibility, effectiveness, and long‐term outcome of transcatheter closure of multiple ASD's using multiple ASO devices. Background: Little is known about the use and long‐term outcome of multiple Amplatzer Septal Occluder (ASO) devices to close multiple atrial septal defects (ASD's). Methods: From May 1997 to June 2006, 33 patients (mean age 38.9 years and mean weight 68 kg) underwent transcatheter closure of multiple ASD's under transesophageal (TEE) or intracardiac echocardiographic (ICE) guidance. Results: Unless not available, the device size chosen to be deployed was ±2 mm larger than the stretched diameter or no more than 30–40% larger than the ICE/TEE 2D diameter. Sixty‐seven devices were deployed in 33 patients. The mean diameters of the larger and smaller defects were 12.9 and 7.7 mm, and the corresponding mean balloon stretched diameters were 19.2 and 12.0 mm, respectively. The mean larger and smaller device diameters were 19.0 and 13.4 mm, respectively. The mean QP: Qs ratio was 1.8:1. The mean fluoroscopy time, and procedure time were 16.4 and 81.6 min respectively. Immediately after the procedure 15 patients had complete closure, 8 had trivial shunt, 9 had small shunt and one had large shunt. Complications included a device embolization within 24 hr and left atrial‐aortic wall erosion and pericardial effusion at 2 years. The mean follow‐up interval was 34.8 + 25.7 months. Conclusions: Device closure of multiple ASD's using multiple ASO's is safe and effective. Continued follow‐up is important to assess the long‐term outcome.Keywords
This publication has 19 references indexed in Scilit:
- Transcatheter atrial septal defect closure: Modified balloon sizing technique to avoid overstretching the defect and oversizing the Amplatzer septal occluderCatheterization and Cardiovascular Interventions, 2005
- Erosion of Amplatzer septal occluder device after closure of secundum atrial septal defects: Review of registry of complications and recommendations to minimize future riskCatheterization and Cardiovascular Interventions, 2004
- Closure of secundum atrial septal defects with the amplatzer septal occluder device: Techniques and problemsCatheterization and Cardiovascular Interventions, 2002
- Comparison between transcatheter and surgical closure of secundum atrial septal defect in children and adultsJournal of the American College of Cardiology, 2002
- Morphological variations of secundum‐type atrial septal defects: Feasibility for percutaneous closure using Amplatzer septal occludersCatheterization and Cardiovascular Interventions, 2001
- Transcatheter closure of multiple atrial septal defects. Initial results and value of two- and three-dimensional transoesophageal echocardiographyEuropean Heart Journal, 2000
- Transcatheter closure of secundum atrial septal defects with the atrial septal defect occlusion system (ASDOS): initial experience in children.Heart, 1996
- Echocardiographic follow-up of atrial septal defect after catheter closure by double-umbrella device.Circulation, 1993
- Transcatheter closure of atrial septal defects. Experimental studies.Circulation, 1989
- Interventional cardiac catheterization in congenital heart diseaseInternational Journal of Cardiology, 1985