A clinical prospective observational cohort study of 15 patients undergoing cervical intervertebral disc replacement. To assess the safety, clinical stability, and capacity of a newly designed cervical intervertebral disc replacement for preserving motion in the cervical spine of patients with degenerative disc disease. Anterior cervical discectomy and interbody fusion results in loss of motion segments and there is evidence of accelerated degenerative changes occurring at adjacent levels. Intervertebral disc replacement may be a valid alternative to fusion. There is a need for cervical disc replacement to be evaluated in prospective studies before it can be adopted as an acceptable surgical technique. The study enrolled 15 patients with cervical radiculopathy or myelopathy and radiologically confirmed cervical disc herniation or posterior vertebral body osteophytes. Eligibility for the study required that patients have either a previous adjacent-level surgical or congenital spinal fusion or radiologic evidence of adjacent-level degenerative disc disease. After decompressive surgery via an anterior approach, all 15 patients received the artificial joint. Follow-up visits were at set intervals and included clinical examination, radiologic assessment, and evaluation by patient-completed questionnaires. In all cases, the artificial joint maintained motion at the operative levels while reestablishing intervertebral height. The procedure was considered safe for experienced spine surgeons to perform, and the device was stable, with no dislocation of components or backing out of screws. Two screws broke, but without any consequence. Improvements in assessment scores were noted. Cervical intervertebral motion can be maintained with the new device, which is clinically stable. Meticulous attention must be paid to the surgical technique to maximize the chances of a good result. The pilot study was successful, although it has yet to be determined what conditions will benefit most from this technology.Keywords
This publication has 18 references indexed in Scilit:
- Strain on Intervertebral Discs After Anterior Cervical Decompression and FusionSpine, 1999
- Radiculopathy and Myelopathy at Segments Adjacent to the Site of a Previous Anterior Cervical Arthrodesis*The Journal of Bone & Joint Surgery, 1999
- Surgical experience with an implanted artificial cervical jointJournal of Neurosurgery, 1998
- The Success of Anterior Cervical Arthrodesis Adjacent to a Previous FusionSpine, 1997
- Intervertebral Disc Replacement: Experimental StudyPublished by Ovid Technologies (Wolters Kluwer Health) ,1997
- The artificial disc: theory, design and materialsBiomaterials, 1996
- In vivo flexion/extension of the normal cervical spineJournal of Orthopaedic Research, 1991
- Accelerated Degeneration of the Segment Adjacent to a Lumbar FusionSpine, 1988
- Roentgenographic Findings of the Cervical Spine in Asymptomatic PeopleSpine, 1986