Effect of a patent foramen ovale on pulmonary gas exchange efficiency at rest and during exercise
Open Access
- 1 May 2011
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 110 (5), 1354-1361
- https://doi.org/10.1152/japplphysiol.01246.2010
Abstract
The prevalence of a patent foramen ovale (PFO) is ∼30%, and this source of right-to-left shunt could result in greater pulmonary gas exchange impairment at rest and during exercise. The aim of this work was to determine if individuals with an asymptomatic PFO (PFO+) have greater pulmonary gas exchange inefficiency at rest and during exercise than subjects without a PFO (PFO−). Separated by 1 h of rest, 8 PFO+ and 8 PFO− subjects performed two incremental cycle ergometer exercise tests to voluntary exhaustion while breathing either room air or hypoxic gas [fraction of inspired O2 (FiO2) = 0.12]. Using echocardiography, we detected small, intermittent boluses of saline contrast bubbles entering directly into the left atrium within 3 heart beats at rest and during both exercise conditions in PFO+. These findings suggest a qualitatively small intracardiac shunt at rest and during exercise in PFO+. The alveolar-to-arterial oxygen difference (AaDo2) was significantly ( P < 0.05) different between PFO+ and PFO− in normoxia (5.9 ± 5.1 vs. 0.5 ± 3.5 mmHg) and hypoxia (10.1 ± 5.9 vs. 4.1 ± 3.1 mmHg) at rest, but not during exercise. However, arterial oxygen saturation was significantly different between PFO+ and PFO− at peak exercise in normoxia (94.3 ± 0.9 vs. 95.8 ± 1.0%) as a result of a significant difference in esophageal temperature (38.4 ± 0.3 vs. 38.0 ± 0.3°C). An asymptomatic PFO contributes to pulmonary gas exchange inefficiency at rest but not during exercise in healthy humans and therefore does not explain intersubject variability in the AaDo2 at maximal exercise.Keywords
This publication has 37 references indexed in Scilit:
- Effect of initial gas bubble composition on detection of inducible intrapulmonary arteriovenous shunt during exercise in normoxia, hypoxia, or hyperoxiaJournal of Applied Physiology, 2011
- Point:Counterpoint: Exercise-induced intrapulmonary shunting is imaginary vs. realJournal of Applied Physiology, 2009
- Counterpoint: Exercise-induced intrapulmonary shunting is realJournal of Applied Physiology, 2009
- Hyperoxia prevents exercise‐induced intrapulmonary arteriovenous shunt in healthy humansThe Journal of Physiology, 2008
- Intrapulmonary shunting and pulmonary gas exchange during normoxic and hypoxic exercise in healthy humansJournal of Applied Physiology, 2008
- Two-dimensional contrast echocardiography in the detection and follow-up of congenital pulmonary arteriovenous malformationsThe American Journal of Cardiology, 1991
- Prevalence of right-to-left atrial shunting in a healthy population: detection by Valsalva maneuver contrast echocardiographyThe American Journal of Cardiology, 1984
- Incidence and Size of Patent Foramen Ovale During the First 10 Decades of Life: An Autopsy Study of 965 Normal HeartsMayo Clinic Proceedings, 1984
- Diagnosis of pulmonary arteriovenous fistula by contrast echocardiographyThe Journal of Pediatrics, 1978
- THE POSITION OF THE OXYGEN DISSOCIATION CURVE OF THE BLOOD IN CYANOTIC CONGENITAL HEART DISEASE 1JCI Insight, 1950