Prospective motion correction using data from optical tracking systems has been previously shown to reduce motion artifacts in MR imaging of the head. We evaluate a novel optical embedded tracking system. The home-built optical embedded tracking system performs image processing within a 7T scanner bore, enabling high speed tracking. Corrected and uncorrected in vivo MR volumes are acquired interleaved using a modified 3D FLASH sequence, and their image quality is assessed and compared. The latency between motion and correction of the slice position was measured to be (19 ± 5) ms, and the tracking noise has a standard deviation no greater than 10 μm/0.005° during conventional MR scanning. Prospective motion correction improved the edge strength by 16 % on average, even though the volunteers were asked to remain motionless during the acquisitions. Using a novel method for validating the effectiveness of in vivo prospective motion correction, we have demonstrated that prospective motion correction using motion data from the embedded tracking system considerably improved image quality.This publication has 28 references indexed in Scilit:
- Prospective motion correction in brain imaging: A reviewMagnetic Resonance in Medicine, 2012
- Isotropic submillimeter fMRI in the human brain at 7 T: Combining reduced field‐of‐view imaging and partially parallel acquisitionsMagnetic Resonance in Medicine, 2012
- Track density imaging (TDI): Validation of super resolution propertyNeuroImage, 2011
- Real‐time rigid body motion correction and shimming using cloverleaf navigatorsMagnetic Resonance in Medicine, 2006
- Magnetic resonance imaging of freely moving objects: prospective real-time motion correction using an external optical motion tracking systemNeuroImage, 2006
- Retrospective motion compensation using variable-density spiral trajectoriesJournal of Magnetic Resonance Imaging, 2005
- Prospective acquisition correction for head motion with image-based tracking for real-time fMRIMagnetic Resonance in Medicine, 2000
- Autocorrection in MR Imaging: Adaptive Motion Correction without Navigator EchoesRadiology, 2000
- Image metric-based correction (Autocorrection) of motion effects: Analysis of image metricsJournal of Magnetic Resonance Imaging, 2000
- Adaptive technique for high-definition MR imaging of moving structures.Radiology, 1989