Abstract
This paper presents a new method for simultaneously selecting the power system stabilizer (PSS) parameters in multimachine power systems. Design of local output feedback power system stabilizer using local signal of the generator (e.g. speed or power) is formulated as a decentralized modal control (DMC) problem. Exact model reduction based on modal control theory is proposed to make the determination of PSS parameters highly efficient. Results obtained from the coordinated tuning of the parameters of three power system stabilizers equipped on a multimachine power system show that exact assignment of the eigenvalues associated with the poorly damped electromechanical modes can be achieved in a very efficient manner.

This publication has 18 references indexed in Scilit: