Measurement of parameters in Indus-2 synchrotron radiation source
- 1 October 2012
- journal article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (10), 103303
- https://doi.org/10.1063/1.4760254
Abstract
The paper presents the measurement of optics parameters in Indus-2 synchrotron radiation source, which include betatron tune, beta function, dispersion function, natural chromaticity, corrected chromaticity, central RF frequency, momentum compaction factor, and linear betatron coupling. Two methods were used for beta function measurement; a conventional quadrupole scan method and a method using the fitting of the orbit response matrix. A robust Levenberg-Marquardt algorithm was used for nonlinear least square fitting of the orbit response matrix. In this paper, detailed methods for the parameter measurements are described. The measured results are discussed and compared with the theoretical values obtained using accelerator simulation code Accelerator Toolbox in MATLAB.Keywords
This publication has 3 references indexed in Scilit:
- Accelerator PhysicsPublished by World Scientific Pub Co Pte Ltd ,2011
- Measurement of optics parameters for HLSNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2001
- Measurement of storage-ring lattice functions: Application to the Pohang Light SourceReview of Scientific Instruments, 1997