Evaluating the Validity of Current Mainstream Wearable Devices in Fitness Tracking Under Various Physical Activities: Comparative Study
Top Cited Papers
Open Access
- 12 April 2018
- journal article
- research article
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 6 (4), e94
- https://doi.org/10.2196/mhealth.9754
Abstract
Background: Wearable devices have attracted much attention from the market in recent years for their fitness monitoring and other health-related metrics; however, the accuracy of fitness tracking results still plays a major role in health promotion. Objective: The aim of this study was to evaluate the accuracy of a host of latest wearable devices in measuring fitness-related indicators under various seminatural activities. Methods: A total of 44 healthy subjects were recruited, and each subject was asked to simultaneously wear 6 devices (Apple Watch 2, Samsung Gear S3, Jawbone Up3, Fitbit Surge, Huawei Talk Band B3, and Xiaomi Mi Band 2) and 2 smartphone apps (Dongdong and Ledongli) to measure five major health indicators (heart rate, number of steps, distance, energy consumption, and sleep duration) under various activity states (resting, walking, running, cycling, and sleeping), which were then compared with the gold standard (manual measurements of the heart rate, number of steps, distance, and sleep, and energy consumption through oxygen consumption) and calculated to determine their respective mean absolute percentage errors (MAPEs). Results: Wearable devices had a rather high measurement accuracy with respect to heart rate, number of steps, distance, and sleep duration, with a MAPE of approximately 0.10, whereas poor measurement accuracy was observed for energy consumption (calories), indicated by a MAPE of up to 0.44. The measurements varied for the same indicator measured by different fitness trackers. The variation in measurement of the number of steps was the highest (Apple Watch 2: 0.42; Dongdong: 0.01), whereas it was the lowest for heart rate (Samsung Gear S3: 0.34; Xiaomi Mi Band 2: 0.12). Measurements differed insignificantly for the same indicator measured under different states of activity; the MAPE of distance and energy measurements were in the range of 0.08 to 0.17 and 0.41 to 0.48, respectively. Overall, the Samsung Gear S3 performed the best for the measurement of heart rate under the resting state (MAPE of 0.04), whereas Dongdong performed the best for the measurement of the number of steps under the walking state (MAPE of 0.01). Fitbit Surge performed the best for distance measurement under the cycling state (MAPE of 0.04), and Huawei Talk Band B3 performed the best for energy consumption measurement under the walking state (MAPE of 0.17). Conclusions: At present, mainstream devices are able to reliably measure heart rate, number of steps, distance, and sleep duration, which can be used as effective health evaluation indicators, but the measurement accuracy of energy consumption is still inadequate. Fitness trackers of different brands vary with regard to measurement of indicators and are all affected by the activity state, which indicates that manufacturers of fitness trackers need to improve their algorithms for different activity states.Keywords
Other Versions
This publication has 29 references indexed in Scilit:
- Physical activity and sedentary behavior patterns using accelerometry from a national sample of United States adultsInternational Journal of Behavioral Nutrition and Physical Activity, 2015
- Validity of Consumer-Based Physical Activity MonitorsMedicine & Science in Sports & Exercise, 2014
- Validation of the Fitbit One activity monitor device during treadmill walkingJournal of Science and Medicine in Sport, 2014
- A Comparison of Energy Expenditure Estimation of Several Physical Activity MonitorsMedicine & Science in Sports & Exercise, 2013
- Comparison of steps and energy expenditure assessment in adults of Fitbit Tracker and Ultra to the Actical and indirect calorimetryJournal of Medical Engineering & Technology, 2013
- Validation of Pattern-Recognition Monitors in Children Using Doubly Labeled WaterMedicine & Science in Sports & Exercise, 2013
- Movement toward a novel activity monitoring deviceSleep and Breathing, 2011
- Validation of the SenseWear Armband at high intensity exerciseEuropean Journal of Applied Physiology, 2010
- Estimation of Free‐Living Energy Expenditure Using a Novel Activity Monitor Designed to Minimize ObtrusivenessObesity, 2010