Effect of Ultrasonic Parameters on Electrochemical Chloride Removal and Rebar Repassivation of Reinforced Concrete

Abstract
Electrochemical chloride removal (ECR) from reinforced concrete can be considered as an environment-friendly technique since it can reduce the environmental issues arising from demolition and reconstruction. In this study, we used ultrasonic waves to promote the ECR efficiency without increasing the current density so as to shorten the overall power-on time, lowering the power consumption and electricity-induced material damage. Rebar-embedded cement mortar specimens were prepared and a set of ultrasonic-assisted ECR test devices was designed. For obtaining the optimal parameters, different ultrasonic frequencies and powers were adopted to conduct the ECR test. After that, the discharged and residual chloride ion amounts were detected to characterize the ECR efficiency. The corrosion behavior of rebar was characterized by electrochemical method. It was found that ultrasonic waves can not only promote the discharge of chloride ions, but also promote the passivation process of steel bar. For this investigation, the ultrasonic waves with a frequency of 40 Hz and a power of 60 W had the best auxiliary effect and could reduce the work time by 64%. It is considered that the ultrasound-assisted method has potential to promote the application possibilities of the ECR technique.
Funding Information
  • National Natural Science Foundation of China (51609075, 51778209)
  • Fundamental Research Funds for the Central Universities (2018B02314)
  • National Key Research and Development Program of China (2018YFC15087040)
  • Guangxi institute of water resources research (GXHRI-WEMS-2019-05)

This publication has 22 references indexed in Scilit: