To evaluate the stability and capsular bag opacification of a smooth or a patterned silicone protective membrane implanted in the bag with secondary placement of an intraocular lens (IOL). John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Experimental study. Twelve New Zealand rabbits had bilateral implantation of a protective membrane and an IOL or an IOL alone. Three groups of 8 eyes each received the IOL and the smooth protective membrane, the IOL and the patterned membrane, or the IOL alone. Slitlamp examination was performed weekly for 4 weeks. The rabbits were then humanely killed and their globes enucleated. Capsular bag opacification was scored based on the Miyake-Apple view, and the eyes underwent histopathology. At 4 weeks, the mean central posterior capsule opacification (PCO) score was 0.28 ± 0.32 (SD) in all eyes with a protective membrane and 2.08 ± 1.28 in eyes with the IOL alone (P < .00001, Student t test). Peripheral PCO and Soemmerring ring formation were also significantly less in eyes with the protective membrane. Histopathologically, the posterior capsules were relatively clear in most IOLs with the protective membrane. The smooth and patterned protective membranes showed a significant difference in overall capsular bag opacification formation compared with the IOLs without the membrane. The circular geometry of the protective membrane led to expansion of the capsular bag and appeared to prevent capsular bag opacification. Further studies are warranted to assess whether the pattern on the device's posterior surface further enhances this effect. No author has a financial or proprietary interest in any material or method mentioned.Keywords
This publication has 16 references indexed in Scilit:
- Capsular bag opacification with a new accommodating intraocular lensJournal of Cataract & Refractive Surgery, 2013
- Prevention of capsular bag opacification with a new hydrophilic acrylic disk-shaped intraocular lensJournal of Cataract & Refractive Surgery, 2011
- Efficacy and safety of capsular bending ring implantation to prevent posterior capsule opacificationJournal of Cataract & Refractive Surgery, 2008
- Alignment of corneal and lens epithelial cells by co-operative effects of substratum topography and DC electric fieldsBiomaterials, 2008
- Synchrony dual-optic accommodating intraocular lensJournal of Cataract & Refractive Surgery, 2007
- Interlenticular opacification: Dual-optic versus piggyback intraocular lensesJournal of Cataract & Refractive Surgery, 2006
- Experimental evaluation of the Corneal Concept 360 intraocular lens with the Miyake-Apple viewJournal of Cataract & Refractive Surgery, 2005
- Capsular bag opacification after experimental implantation of a new accommodating intraocular lens in rabbit eyesJournal of Cataract & Refractive Surgery, 2004
- Posterior Capsule OpacificationInternational Ophthalmology Clinics, 2001
- Posterior capsule opacificationSurvey of Ophthalmology, 1992