Patient-Specific Computational Modeling of Keratoconus Progression and Differential Responses to Collagen Cross-linking
Open Access
- 1 November 2011
- journal article
- cornea
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 52 (12), 9174-9187
- https://doi.org/10.1167/iovs.11-7395
Abstract
Purpose.: To model keratoconus (KC) progression and investigate the differential responses of central and eccentric cones to standard and alternative collagen cross-linking (CXL) patterns. Methods.: Three-dimensional finite element models (FEMs) were generated with clinical tomography and IOP measurements. Graded reductions in regional corneal hyperelastic properties and thickness were imposed separately in the less affected eye of a KC patient. Topographic results, including maximum curvature and first-surface, higher-order aberrations (HOAs), were compared to those of the more affected contralateral eye. In two eyes with central and eccentric cones, a standard broad-beam CXL protocol was simulated with 200- and 300-μm treatment depths and compared to spatially graded broad-beam and cone-centered CXL simulations. Results.: In a model of KC progression, maximum curvature and HOA increased as regional corneal hyperelastic properties were decreased. A topographic cone could be generated without a reduction in corneal thickness. Simulation of standard 9-mm-diameter CXL produced decreases in corneal curvature comparable to clinical reports and affected cone location. A 100-μm increase in CXL depth enhanced flattening by 24% to 34% and decreased HOA by 22% to 31%. Topographic effects were greatest with cone-centered CXL simulations. Conclusions.: Progressive hyperelastic weakening of a cornea with subclinical KC produced topographic features of manifest KC. The clinical phenomenon of topographic flattening after CXL was replicated. The magnitude and higher-order optics of this response depended on IOP and the spatial distribution of stiffening relative to the cone location. Smaller diameter simulated treatments centered on the cone provided greater reductions in curvature and HOA than a standard broad-beam CXL pattern.This publication has 57 references indexed in Scilit:
- Epithelial Thickness Profile as a Method to Evaluate the Effectiveness of Collagen Cross-Linking Treatment After Corneal EctasiaJournal of Refractive Surgery, 2011
- Patient-Specific Modeling of Corneal Refractive Surgery Outcomes and Inverse Estimation of Elastic Property ChangesJournal of Biomechanical Engineering, 2010
- Epithelial, Stromal, and Total Corneal Thickness in Keratoconus: Three-dimensional Display With Artemis Very-high Frequency Digital UltrasoundJournal of Refractive Surgery, 2010
- Corneal Stiffness Affects IOP Elevation during Rapid Volume Change in the EyeInvestigative Ophthalmology & Visual Science, 2009
- A Nonlinear Anisotropic Viscoelastic Model for the Tensile Behavior of the Corneal StromaJournal of Biomechanical Engineering, 2008
- CLMICornea, 2008
- Second-Harmonic Imaging Microscopy of Normal Human and Keratoconus CorneaInvestigative Ophthalmology & Visual Science, 2007
- Biomechanics and wound healing in the corneaExperimental Eye Research, 2006
- SOD1: A Candidate Gene for KeratoconusInvestigative Ophthalmology & Visual Science, 2006
- Gene Expression Profile Studies of Human Keratoconus Cornea for NEIBank: A Novel Cornea-Expressed Gene and the Absence of Transcripts for Aquaporin 5Investigative Ophthalmology & Visual Science, 2005