Transverse connectors providing increased stability to the cervical spine rod-screw construct: an in vitro human cadaveric study
- 1 June 2011
- journal article
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 14 (6), 719-725
- https://doi.org/10.3171/2011.1.spine10411
Abstract
The object of this study was to determine if the addition of transverse connectors (TCs) to a rod-screw construct leads to increased stabilization of the cervical spine. Eleven human cadaveric cervical spines (C2-T1) were used to examine the effect of adding connectors to a C3-7 rod-screw construct in 3 models of instability: 1) C3-6 wide laminectomy, 2) wide laminectomy and 50% foraminotomy at C4-5 and C5-6, and 3) wide laminectomy with full medial to lateral foraminotomy. Following each destabilization procedure, specimens were tested with no TC, 1 TC between the C-5 screws, and 2 TCs between the C-4 and C-6 screws. Testing of the connectors was conducted in random order. Specimens were subjected to ± 2 Nm of torque in flexion and extension, lateral bending, and axial rotation. Range of motion was determined for each experimental condition. Statistical comparisons were made between the destabilized and intact conditions, and between the addition of TCs and the absence of TCs. The progressive destabilization procedures significantly increased motion. The addition of TCs did not significantly change motion in flexion and extension. Lateral bending was significantly decreased with 2 connectors, but not with 1 connector. The greatest effect was on axial rotation. In general, 2 TCs were more restrictive than 1 TC, and decreased motion 10% more than fixation alone. Regardless of the degree of cervical destabilization, 1 or 2 TCs decreased motion compared with rods and screws alone. Axial rotation was most affected. Transverse connectors effectively increase the rigidity of rod-screw constructs in the cervical spine. Severe cervical instability can be overcome with the use of 2 TCs, but in cases in which 2 cannot be used, 1 should be adequate and superior to none.Keywords
This publication has 36 references indexed in Scilit:
- Posterior-only Stabilization of 2-column and 3-column Injuries at the Cervicothoracic JunctionJournal of Spinal Disorders & Techniques, 2009
- Biomechanical Contribution of Transverse Connectors to Segmental Stability Following Long Segment Instrumentation With Thoracic Pedicle ScrewsSpine, 2008
- Stabilizing Potential of Anterior, Posterior, and Circumferential Fixation for Multilevel Cervical ArthrodesisSpine, 2007
- Motion Compensation Associated With Single-Level Cervical Fusion: Where Does the Lost Motion Go?Spine, 2006
- Posterior Cervical Lateral Mass Screw FixationJournal of Spinal Disorders & Techniques, 2005
- Segmental pedicle screw fixation or cross-links in multilevel lumbar constructs a biomechanical analysisThe Spine Journal, 2001
- Tuberculosis of the Long Bone in ChildrenClinical Orthopaedics and Related Research, 1997
- Cervical Spine Strength After Facet Injury and Spine Plate ApplicationSpine, 1991
- Titanium Wire Internal Fixation for Stabilization of Injury of the Cervical Spine: Clinical Results and Postoperative Magnetic Resonance Imaging of the Spinal CordNeurosurgery, 1989
- Three‐dimensional load‐displacement curves due to froces on the cervical spineJournal of Orthopaedic Research, 1986