Nano-HPLC-inductively coupled plasma mass spectrometry for arsenic speciation
- 21 June 2007
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 22 (9), 1199-1205
- https://doi.org/10.1039/b703257a
Abstract
A nano-high performance liquid chromatography-inductively coupled plasma mass spectrometry (nano-HPLC-ICPMS) method is developed, using a demountable direct injection high efficiency nebulizer (d-DIHEN), to reduce sample and mobile phase consumption, minimize organic waste generation, decrease analysis time, and enhance separation efficiency. A HPLC column (50 mm × 0.3 mm id), packed with 3.5 μm C18 material, is explored for chromatographic separation of five arsenic species naturally present in the environment or introduced as a pollutant: sodium (meta)arsenite [As(III)], arsenic acid [As(V)], dimethylarsenic acid (DMA), disodium methylarsenate (MA), and p-arsanilic acid (p-ASA). A fast chromatographic separation of five arsenic species is achieved in less than 12 min at a solution flow rate of 0.9 μL min−1 using a 50 nL sample injection. The HPLC-ICPMS interface provides well defined flow injection profiles at various concentrations, giving a correlation coefficient of 0.999 for each individual arsenic species calibration curve. Precision values for peak height and area of five arsenic species range from 0.5 to 6.5% RSD and absolute detection limits are within 0.4 to 5.4 pg arsenic, which are comparable to previously reported data at higher solution uptake rates (20 μL min−1 to 1 mL min−1) and larger sample injection volumes (20–100 μL).Keywords
This publication has 40 references indexed in Scilit:
- Environmental Contamination of Arsenic and its Toxicological Impact on HumansEnvironmental Chemistry, 2005
- Determination of arsenic species: A critical review of methods and applications, 2000–2003The Analyst, 2004
- Arsenic speciation analysisTalanta, 2002
- A study of method robustness for arsenic speciation in drinking water samples by anion exchange HPLC-ICP-MSAnalytical and Bioanalytical Chemistry, 2002
- Automated, continuous, and dynamic speciation of urinary arsenic in the bladder of living organisms using microdialysis sampling coupled on-line with high performance liquid chromatography and hydride generation atomic absorption spectrometryThe Analyst, 2002
- Speciation analysis of arsenic in environmental solids Reference Materials by high-performance liquid chromatography–hydride generation–atomic fluorescence spectrometry following orthophosphoric acid extractionAnalytica Chimica Acta, 2001
- High-speed separation of arsenic compounds using narrow-bore high-performance liquid chromatography on-line with inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 2000
- Comparison of four nebulizer–spray chamber interfaces for the high-performance liquid chromatographic separation of arsenic compounds using inductively coupled plasma mass spectrometric detectionJournal of Analytical Atomic Spectrometry, 1998
- Epidemiological studies on human subjects exposed to arsenic in drinking water in Southeast HungaryArchives of Toxicology, 1992
- Evaluation of health implications of elevated arsenic in well waterWater Research, 1972