To compare the inhibiting effect on posterior capsule opacification (PCO) of a silicone intraocular lens (IOL) with a sharp posterior optic edge (ClariFlex OptiEdge, Advanced Medical Optics) and a silicone IOL with a round optic edge (PhacoFlex SI-40, Advanced Medical Optics). Department of Ophthalmology, University of Vienna, Vienna, Austria. This prospective randomized patient- and examiner-masked study comprised 104 eyes of 52 patients with bilateral age-related cataract. All patients had cataract surgery in both eyes and received a sharp-edged IOL in 1 eye and a round-edged IOL in the other eye. Postoperative examinations were at 1 week, 1 and 6 months, and 1 year. Digital slitlamp and retroillumination images were taken of each eye. The amount of PCO was assessed subjectively at the slitlamp and objectively using Automated Quantification of After-Cataract (AQUA) automated-image analysis software. The sharp-edged IOL group had significantly less regeneratory and fibrotic PCO 1 month, 6 months, and 1 year after surgery. The mean AQUA PCO score (scale 0 to 10) was 0.71 in the sharp-edged IOL group and 1.40 in the round-edged IOL group (P<.001). The sharp-edged IOL group had less peripheral fibrotic PCO. There was no significant difference between the 2 IOL groups in patient reports of edge glare. The sharp-edged design of the ClariFlex OptiEdge silicone IOL led to significantly less PCO than the round-edged PhacoFlex SI-40 IOL 1 year postoperatively.Keywords
This publication has 23 references indexed in Scilit:
- Quantification of posterior capsule opacification with round and sharp edge intraocular lensesOphthalmology, 2003
- Comparison of 4 methods for quantifying posterior capsule opacificationJournal of Cataract & Refractive Surgery, 2003
- Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacificationJournal of Cataract & Refractive Surgery, 2002
- Three-year clinical comparison of 3-piece AcrySof and SI-40 silicone intraocular lensesJournal of Cataract & Refractive Surgery, 2002
- Reproducibility of standardized retroillumination photography for quantification of posterior capsule opacificationJournal of Cataract & Refractive Surgery, 2002
- Assessment of anterior capsule opacification: photographic technique and quantificationJournal of Cataract & Refractive Surgery, 2002
- Uveal and capsular biocompatibility of hydrophilic acrylic, hydrophobic acrylic, and silicone intraocular lensesJournal of Cataract & Refractive Surgery, 2002
- Surgical prevention of posterior capsule opacificationJournal of Cataract & Refractive Surgery, 2000
- Update on fixation of rigid and foldable posterior chamber intraocular lenses. part II: choosing the correct haptic fixation and intraocular lens design to help eradicate posterior capsule opacificationOphthalmology, 1999
- A systematic overview of the incidence of posterior capsule opacificationOphthalmology, 1998