Ingestion of Acidic Foods Mimics Gastroesophageal Reflux During pH Monitoring
- 1 October 2005
- journal article
- Published by Springer Science and Business Media LLC in Digestive Diseases and Sciences
- Vol. 50 (10), 1916-1920
- https://doi.org/10.1007/s10620-005-2961-6
Abstract
Ingestion of acidic foods may produce artifactual drops in pH to < 4 that may be difficult to differentiate from a true acid reflux event. We aimed to evaluate intraesophageal pH changes during the ingestion of acidic food and describe the frequency and implications of acidic food ingestion on ambulatory pH monitoring. Ten normal volunteers (six females; mean age, 34) underwent combined impedance-pH testing with a pH electrode placed 5 cm above the lower esophageal sphincter. Each volunteer received 50 ml each of acidic foods in random order. Nadir and mean pH for 30 sec after ingestion of each substance were recorded. Subsequently 100 randomly selected reflux monitor diaries were reviewed, searching for ingestion of acidic foods, and 100 pH tracings were reviewed to evaluate the impact of including/excluding meal periods on percentage time pH < 4 and DeMeester scores. All foods produced abrupt drops to pH < 4, in 80% of cases exceeding 30 sec. During ambulatory pH monitoring 78% of patients recorded ingestion of at least 1 of the 10 tested substances during meals, the majority admitting ingesting carbonated beverages. Not excluding meal periods would have led to the misinterpretation of 6-16% of tracings, depending on the criteria used to identify abnormal acid exposure. We conclude that ingestion of acidic foods is frequent and carries the risk of overdiagnosing GERD. Current findings support the recommendations to carefully instruct patients to record all oral intake and to exclude meal periods from the analysis.Keywords
This publication has 9 references indexed in Scilit:
- Impact of ingested liquids on 24-hour ambulatory pH tests.Digestive Diseases and Sciences, 1998
- Exclusion of the Meal Period Improves the Clinical Reliability of Esophageal pH MonitoringJournal of Clinical Gastroenterology, 1997
- Exclusion of meal periods from ambulatory 24-hour pH monitoring May improve diagnosis of esophageal acid refluxDigestive Diseases and Sciences, 1994
- pH monitoring: The gold standard in detection of gastrointestinal reflux disease?Dysphagia, 1993
- Ambulatory 24-h esophageal pH monitoring: normal values, optimal thresholds, specificity, sensitivity, and reproducibility.1992
- Prolonged intraesophageal pH monitoring with 16-Hr overnight recordingDigestive Diseases and Sciences, 1992
- Intraesophageal pH Monitoring after Breakfast + Lunch in Gastroesophageal RefluxJournal of Clinical Gastroenterology, 1988
- 2 pH Measurement in the oesophagusBailliere's Clinical Gastroenterology, 1987
- The Physiology of HeartburnAnnals of Internal Medicine, 1961