Diazonium−Protein Adducts for Graphite Electrode Microarrays Modification: Direct and Addressed Electrochemical Immobilization
- 1 December 2005
- journal article
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 127 (51), 18328-18332
- https://doi.org/10.1021/ja056946w
Abstract
Diazonium cation electrodeposition was investigated for the direct and electro-addressed immobilization of proteins. For the first time, this reaction was triggered directly onto diazonium-modified proteins. Screen-printed (SP) graphite electrode microarrays were studied as active support for this immobilization. A 10-microelectrode (eight working electrodes, 0.2 mm2 each; one reference; and one auxiliary) setup was used to study the addressing possibilities of the method. These electrode microarrays were shown to be able to covalently graft diazonium cations through electrochemical reduction. Cyclic voltammetry and X-ray photoelectron spectroscopy were used to characterize the electrochemical grafting onto our SP graphite surface and suggested that a diazonium monolayer was deposited. Rabbit and human immunoglobulins (IgGs) were then chemically coupled to an aniline derivative (4-carboxymethylaniline), followed by diazotation to form an aryl diazonium function available for the electrodeposition. These modified proteins were both successfully electro-addressed at the surface of the graphite electrodes without cross-talk or interference. The immuno-biochip obtained using this novel approach enabled the specific detection of anti-rabbit IgG antibodies with a detection limit of 50 fmol of protein. A promising strategy to immobilize markedly different biological entities was then presented, providing an excellent spatial specificity of the electro-addressing.Keywords
This publication has 36 references indexed in Scilit:
- Electroaddressed immobilization of recombinant HIV-1 P24 capsid protein onto screen-printed arrays for serological testingAnalytical Biochemistry, 2005
- Impedance-based detection of DNA sequences using a silicon transducer with PNA as the probe layerNucleic Acids Research, 2004
- Electrochemically controlled solid-phase microextraction and preconcentration using polypyrrole coated microarray electrodes in a flow systemThe Analyst, 2003
- Characterization and Optimization of Peptide Arrays for the Study of Epitope−Antibody Interactions Using Surface Plasmon Resonance ImagingAnalytical Chemistry, 2002
- Genotyping on a Complementary Metal Oxide Semiconductor Silicon Polymerase Chain Reaction Chip with Integrated DNA MicroarrayAnalytical Chemistry, 2002
- Impedance based DNA chip for direct Tm measurementTalanta, 2002
- Redox-Active Nucleic-Acid Replica for the Amplified Bioelectrocatalytic Detection of Viral DNAJournal of the American Chemical Society, 2002
- Electronic nose based on conducting polymers for the quality control of the olive oil aroma: Discrimination of quality, variety of olive and geographic originAnalytica Chimica Acta, 2001
- Microarray fabrication with covalent attachment of DNA using Bubble Jet technologyNature Biotechnology, 2000
- Controlled electrochemical preparation of enzymatic layers for the design of amperometric biosensorsElectroanalysis, 1993