Mortality associated with tiotropium mist inhaler in patients with chronic obstructive pulmonary disease: systematic review and meta-analysis of randomised controlled trials
Open Access
- 14 June 2011
- Vol. 342 (jun14 1), d3215
- https://doi.org/10.1136/bmj.d3215
Abstract
Objective To systematically review the risk of mortality associated with long term use of tiotropium delivered using a mist inhaler for symptomatic improvement in chronic obstructive pulmonary disease. Data sources Medline, Embase, the pharmaceutical company clinical trials register, the US Food and Drug Administration website, and ClinicalTrials.gov for randomised controlled trials from inception to July 2010. Study selection Trials were selected for inclusion if they were parallel group randomised controlled trials of tiotropium solution using a mist inhaler (Respimat Soft Mist Inhaler, Boehringer Ingelheim) versus placebo for chronic obstructive pulmonary disease; the treatment duration was more than 30 days, and they reported data on mortality. Relative risks of all cause mortality were estimated using a fixed effect meta-analysis, and heterogeneity was assessed with the I2 statistic. Results Five randomised controlled trials were eligible for inclusion. Tiotropium mist inhaler was associated with a significantly increased risk of mortality (90/3686 v 47/2836; relative risk 1.52, 95% confidence interval, 1.06 to 2.16; P=0.02; I2=0%). Both 10 µg (2.15, 1.03 to 4.51; P=0.04; I2=9%) and 5 µg (1.46, 1.01 to 2.10; P=0.04; I2=0%) doses of tiotropium mist inhaler were associated with an increased risk of mortality. The overall estimates were not substantially changed by sensitivity analysis of the fixed effect analysis of the five trials combined using the random effects model (1.45, 1.02 to 2.07; P=0.04), limiting the analysis to three trials of one year’s duration each (1.50, 1.05 to 2.15), or the inclusion of additional data on tiotropium mist inhaler from another investigational drug programme (1.42, 1.01 to 2.00). The number needed to treat for a year with the 5 µg dose to see one additional death was estimated to be 124 (95% confidence interval 52 to 5682) based on the average control event rate from the long term trials. Conclusions This meta-analysis explains safety concerns by regulatory agencies and indicates a 52% increased risk of mortality associated with tiotropium mist inhaler in patients with chronic obstructive pulmonary disease.This publication has 26 references indexed in Scilit:
- A one-year trial of tiotropium Respimat® plus usual therapy in COPD patientsRespiratory Medicine, 2010
- Tiotropium and risk for fatal and nonfatal cardiovascular events in patients with chronic obstructive pulmonary disease: Systematic review with meta-analysisRespiratory Medicine, 2009
- A 4-Year Trial of Tiotropium in Chronic Obstructive Pulmonary DiseaseThe New England Journal of Medicine, 2008
- Inhaled Anticholinergics and Risk of Major Adverse Cardiovascular Events in Patients With Chronic Obstructive Pulmonary DiseaseJAMA, 2008
- A randomized study of tiotropium Respimat® Soft MistTM Inhaler vs. ipratropium pMDI in COPDRespiratory Medicine, 2008
- Uncertainty in heterogeneity estimates in meta-analysesBMJ, 2007
- Much ado about nothing: a comparison of the performance of meta‐analytical methods with rare eventsStatistics in Medicine, 2006
- Cardiovascular Disease in Patients with Chronic Obstructive Pulmonary Disease, Saskatchewan Canada: Cardiovascular Disease in COPD PatientsAnnals of Epidemiology, 2006
- Measuring inconsistency in meta-analysesBMJ, 2003
- Is there any association between inhaled ipratropium and mortality in patients with COPD and asthma?Respiratory Medicine, 2003