Minimally invasive percutaneous transpedicular screw fixation: increased accuracy and reduced radiation exposure by means of a novel electromagnetic navigation system
Open Access
- 14 December 2010
- journal article
- research article
- Published by Springer Science and Business Media LLC in Acta Neurochirurgica
- Vol. 153 (3), 589-596
- https://doi.org/10.1007/s00701-010-0882-4
Abstract
Background Minimally invasive percutaneous pedicle screw instrumentation methods may increase the need for intraoperative fluoroscopy, resulting in excessive radiation exposure for the patient, surgeon, and support staff. Electromagnetic field (EMF)-based navigation may aid more accurate placement of percutaneous pedicle screws while reducing fluoroscopic exposure. We compared the accuracy, time of insertion, and radiation exposure of EMF with traditional fluoroscopic percutaneous pedicle screw placement. Methods Minimally invasive pedicle screw placement in T8 to S1 pedicles of eight fresh-frozen human cadaveric torsos was guided with EMF or standard fluoroscopy. Set-up, insertion, and fluoroscopic times and radiation exposure and accuracy (measured with post-procedural computed tomography) were analyzed in each group. Results Sixty-two pedicle screws were placed under fluoroscopic guidance and 60 under EMF guidance. Ideal trajectories were achieved more frequently with EMF over all segments (62.7% vs. 40%; p = 0.01). Greatest EMF accuracy was achieved in the lumbar spine, with significant improvements in both ideal trajectory and reduction of pedicle breaches over fluoroscopically guided placement (64.9% vs. 40%, p = 0.03, and 16.2% vs. 42.5%, p = 0.01, respectively). Fluoroscopy time was reduced 77% with the use of EMF (22 s vs. 5 s per level; p < 0.0001) over all spinal segments. Radiation exposure at the hand and body was reduced 60% ( p = 0.058) and 32% ( p = 0.073), respectively. Time for insertion did not vary between the two techniques. Conclusions Minimally invasive pedicle screw placement with the aid of EMF image guidance reduces fluoroscopy time and increases placement accuracy when compared with traditional fluoroscopic guidance while adding no additional time to the procedure.Keywords
This publication has 41 references indexed in Scilit:
- Electromagnetic navigation for percutaneous guide-wire insertion: Accuracy and efficiency compared to conventional fluoroscopic guidanceNeuroImage, 2009
- Percutaneous laser discectomy guided with stereotactic computer-assisted surgical navigationLasers in Surgery and Medicine, 2009
- Sterility of C-arm Fluoroscopy During Spinal SurgerySpine, 2008
- Pedicle Screw Placement AccuracySpine, 2007
- Accuracy Over Space and Time of Computer-Assisted Fluoroscopic Navigation in the Lumbar Spine In VivoJournal of Spinal Disorders & Techniques, 2006
- Minimally Invasive Transmuscular Pedicle Screw Fixation of the Thoracic and Lumbar SpineOperative Neurosurgery, 2006
- Pedicle Screw Placement in the Thoracic SpineSpine, 2005
- Three-dimensional fluoroscopy-guided percutaneous thoracolumbar pedicle screw placementJournal of Neurosurgery: Spine, 2003
- Minimally Invasive Lumbar FusionSpine, 2003
- A Biomechanical Study of Intrapeduncular Screw Fixation in the Lumbosacral SpineClinical Orthopaedics and Related Research, 1986