Integrated circuit amplifiers for multi-electrode intracortical recording
- 12 January 2009
- journal article
- review article
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 6 (1), 012001
- https://doi.org/10.1088/1741-2560/6/1/012001
Abstract
Significant progress has been made in systems that interpret the electrical signals of the brain in order to control an actuator. One version of these systems senses neuronal extracellular action potentials with an array of up to 100 miniature probes inserted into the cortex. The impedance of each probe is high, so environmental electrical noise is readily coupled to the neuronal signal. To minimize this noise, an amplifier is placed close to each probe. Thus, the need has arisen for many amplifiers to be placed near the cortex. Commercially available integrated circuits do not satisfy the area, power and noise requirements of this application, so researchers have designed custom integrated-circuit amplifiers. This paper presents a comprehensive survey of the neural amplifiers described in publications prior to 2008. Methods to achieve high input impedance, low noise and a large time-constant high-pass filter are reviewed. A tutorial on the biological, electrochemical, mechanical and electromagnetic phenomena that influence amplifier design is provided. Areas for additional research, including sub-nanoampere electrolysis and chronic cortical heating, are discussed. Unresolved design concerns, including teraohm circuitry, electrical overstress and component failure, are identified.Keywords
This publication has 203 references indexed in Scilit:
- Wavelet filtering before spike detection preserves waveform shape and enhances single-unit discriminationJournal of Neuroscience Methods, 2008
- Single-walled carbon nanotubes deposited on surface electrodes to improve interface impedancePhysiological Measurement, 2008
- Fever, febrile seizures and epilepsyTrends in Neurosciences, 2007
- Implantable microscale neural interfacesBiomedical Microdevices, 2007
- Predicted current densities in the brain during transcranial electrical stimulationClinical Neurophysiology, 2006
- An Implantable CMOS Front-End System for Nerve-Signal SensorsAnalog Integrated Circuits and Signal Processing, 2005
- In vitroassessment of tissue heating near metallic medical implants by exposure to pulsed radio frequency diathermyPhysics in Medicine & Biology, 2003
- An improved model of man for ESD applicationsJournal of Electrostatics, 2000
- An implantable CMOS circuit interface for multiplexed microelectrode recording arraysIEEE Journal of Solid-State Circuits, 1992
- Properties of the Electrical Double Layer at a Mercury Surface. II. The Effect of Frequency on the Capacity and Resistance of Ideal Polarized Electrodes1Journal of the American Chemical Society, 1946