Liquid chromatography coupled to mass spectrometry (LC−MS) and tandem mass spectrometry (LC−MS/MS) has become a standard technique for analyzing complex peptide mixtures to determine composition and relative abundance. Several high-throughput proteomics techniques attempt to combine complementary results from multiple LC−MS and LC−MS/MS analyses to provide more comprehensive and accurate results. To effectively collate and use results from these techniques, variations in mass and elution time measurements between related analyses need to be corrected using algorithms designed to align the various types of data: LC−MS/MS versus LC−MS/MS, LC−MS versus LC−MS/MS, and LC−MS versus LC−MS. Described herein are new algorithms referred to collectively as liquid chromatography-based mass spectrometric warping and alignment of retention times of peptides (LCMSWARP), which use a dynamic elution time warping approach similar to traditional algorithms that correct for variations in LC elution times using piecewise linear functions. LCMSWARP is compared to the equivalent approach based upon linear transformation of elution times. LCMSWARP additionally corrects for temporal drift in mass measurement accuracies. We also describe the alignment of LC−MS results and demonstrate their application to the alignment of analyses from different chromatographic systems, showing the suitability of the present approach for more complex transformations.Keywords
This publication has 20 references indexed in Scilit:
- Analysis of the Salmonella typhimurium Proteome through Environmental Response toward Infectious ConditionsMolecular & Cellular Proteomics, 2006
- PRISM: A data management system for high‐throughput proteomicsProteomics, 2006
- Signal Maps for Mass Spectrometry-based Comparative ProteomicsMolecular & Cellular Proteomics, 2006
- Advances in proteomics data analysis and display using an accurate mass and time tag approachMass Spectrometry Reviews, 2006
- A Comprehensive Two-Dimensional Retention Time Alignment Algorithm To Enhance Chemometric Analysis of Comprehensive Two-Dimensional Separation DataAnalytical Chemistry, 2005
- Multicomponent Internal Recalibration of an LC−FTICR-MS Analysis Employing a Partially Characterized Complex Peptide Mixture: Systematic and Random ErrorsAnalytical Chemistry, 2005
- Informatics Platform for Global Proteomic Profiling and Biomarker Discovery Using Liquid Chromatography-Tandem Mass SpectrometryMolecular & Cellular Proteomics, 2004
- TANDEM: matching proteins with tandem mass spectraBioinformatics, 2004
- Empirical Statistical Model To Estimate the Accuracy of Peptide Identifications Made by MS/MS and Database SearchAnalytical Chemistry, 2002
- Probability-based protein identification by searching sequence databases using mass spectrometry dataElectrophoresis, 1999