Indoor Climate Conditions and Ventilation Performance in Estonian Lightweight Detached Houses
- 1 December 2006
- journal article
- research article
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 15 (6), 555-569
- https://doi.org/10.1177/1420326x06073076
Abstract
Field measurements of the indoor climate and ventilation performance have been carried out in 28 lightweight timber-frame detached houses occupied by single families during the years 2003-05 in Estonia. The temperature and relative humidity (RH) were continuously measured in bedrooms, living rooms and outdoors for each house at 1-h intervals over a 1-year period. The air change rates were calculated on the basis of the measured exhaust air flows. An extended period of high indoor temperatures during summer suggests that thermal comfort was not considered in the original design. During winter, large variations in temperature showed that problems existed with temperature control systems. During summer, only 13% and during winter, 45% of the rooms met the standard recommendations (with 5% excess) for temperatures in the lowest indoor climate category. This correspondence to standard recommendations was highest for the houses with balanced ventilation. The average ventilation air change rate at the level used by the occupants with a mechanical ventilation system was 0.41ach (13.3L·s−1 per person and 0.28L·s−1·m−2). The performance of the ventilation had a significant influence on the average daily amplitude of the indoor temperature and humidity. According to a questionnaire, noise was associated with mechanical ventilation and stuffy air with natural ventilation. Fluctuating room temperature, cold floors and draught from electric sockets during winter were related to houses with air leakage of the building envelope 3m3·h−1·−2) at 50Pa.Keywords
This publication has 8 references indexed in Scilit:
- Dampness in buildings as a risk factor for health effects, EUROEXPO: a multidisciplinary review of the literature (1998-2000) on dampness and mite exposure in buildings and health effectsIndoor Air, 2004
- Dampness in Buildings and HealthIndoor Air, 2001
- Reducing relative humidity to control the house dust mite Dermatophagoides farinaeJournal of Allergy and Clinical Immunology, 1999
- Life cycle and reproduction of house‐dust mites: environmental factors influencing mite populationsAllergy, 1998
- Impact of Temperature and Humidity on Perception of Indoor Air Quality During Immediate and Longer Whole-Body ExposuresIndoor Air, 1998
- Indoor Climate and the Performance of Ventilation in Finnish ResidencesIndoor Air, 1992
- Sick building syndrome, sensation of dryness and thermal comfort in relation to room temperature in an office building: Need for individual control of temperatureEnvironment International, 1989
- House‐Dust Mites and Absolute Indoor HumidityAllergy, 1983