Value of point-of-care ultrasonography compared with computed tomography scan in detecting potential life-threatening conditions in blunt chest trauma patients
Open Access
- 4 August 2020
- journal article
- research article
- Published by Springer Science and Business Media LLC in The Ultrasound Journal
- Vol. 12 (1), 1-10
- https://doi.org/10.1186/s13089-020-00183-6
Abstract
Background Ultrasonography is a suitable modality that can potentially improve patient care, saving time and lives. Purpose This article has evaluated the caveats and pitfalls of point-of-care ultrasonography in the diagnosis of pneumothorax, hemothorax and contusion. Materials and methods This prospective study was performed in 157 patients with blunt chest trauma in 3 university hospitals. Ultrasonography was performed by 2 board-certified emergency medicine specialists and an emergency medicine resident PGY-3 after passing the training process successfully. Results The false-negative cases were not significantly correlated with accompanying traumatic injuries. Lung ultrasonography accompanied by chest physical examination show accuracy 91.8. Point-of-care ultrasonography (PoCUS) showed sensitivity 75.0%, specificity 100%, positive-predictive value (PPV) of 100% and a negative-predictive value (NPV) of 94.9% for the diagnosis of pneumothorax. For hemothorax, bedside PoCUS had a sensitivity of 45.4%, specificity of 100%, PPV of 100% and NPV of 91.8%. PoCUS was assessed 58.1% sensitive and 100% specific for detecting lung contusion with positive-predictive value (PPV) of 100% and a negative-predictive value (NPV) of 86.3%. Performing US resulted in no false-positive cases. Conclusions Point-of-care ultrasonography was highly sensitive to detect pneumothorax and can be beneficial for the disposition of stable patients and to detect PTX in unstable patients before transferring to the operating room. It is also moderately appropriate for the diagnosis of hemothorax and lung contusion compared to the gold standard, CT scan. It is essential to consider the false-negative and false-positive instances of lung ultrasound in various situations to enhance management and disposition of blunt thoracic injuries.Keywords
Funding Information
- Sina Trauma and Surgery Research Center (33207-38-03-95)
This publication has 34 references indexed in Scilit:
- The V-line: a sonographic aid for the confirmation of pleural fluidThe Ultrasound Journal, 2012
- Systematic review of predictive performance of injury severity scoring toolsScandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 2012
- Acute lung injury and the acute respiratory distress syndrome in the injured patientScandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 2012
- Management of traumatic occult pneumothoraxResuscitation, 2010
- Sensitivity of Bedside Ultrasound and Supine Anteroposterior Chest Radiographs for the Identification of Pneumothorax After Blunt TraumaAcademic Emergency Medicine, 2010
- Chest sonography: a useful tool to differentiate acute cardiogenic pulmonary edema from acute respiratory distress syndromeCardiovascular Ultrasound, 2008
- Chest Ultrasonography in Lung ContusionSocial psychiatry. Sozialpsychiatrie. Psychiatrie sociale, 2006
- A Prospective Comparison of Supine Chest Radiography and Bedside Ultrasound for the Diagnosis of Traumatic PneumothoraxAcademic Emergency Medicine, 2005
- Ultrasound diagnosis of occult pneumothorax*Critical Care Medicine, 2005
- THE INJURY SEVERITY SCOREJournal Of Trauma-Injury Infection and Critical Care, 1974