A methodology for determining water saturation limits and moisture equilibrium diagrams of alternative insulation systems
- 1 June 2011
- conference paper
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2011 IEEE International Conference on Dielectric Liquids
Abstract
In recent years one can observe a higher interest in alternative dielectric materials for power transformers. These are for example natural and synthetic esters or aramid fiber based solid insulation materials. In this paper moisture saturation curves of various insulation oils are presented up to a temperature of 140°C, together with the sorption isotherms of Nomex ® pressboard. These lead to adjusted equilibrium charts for moisture diagnosis of transformers with unconventional insulation systems.Keywords
This publication has 2 references indexed in Scilit:
- Water in oil-filled high-voltage equipment part II: water content as physicochemical tools for insulation condition diagnosticIEEE Electrical Insulation Magazine, 2007