Fast, reproducible measurement of the vascular input function in mice using constrained reconstruction and cardiac sampling
- 22 September 2010
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 24 (4), 373-384
- https://doi.org/10.1002/nbm.1601
Abstract
Dynamic contrast‐enhanced MRI is often used to assess the response to therapy in small animal models of cancer. Rigorous quantification of dynamic contrast‐enhanced MRI data using common pharmacokinetic models requires dynamic determination of the concentration of contrast in tumor tissue and in blood. Measurement of the blood concentration, or vascular input function (VIF), requires high temporal resolution and is prone to distortion as a result of flow and partial volume artifacts when measured in local blood vessels. We have developed a strategy for the robust measurement of VIF in mice that uses a constrained reconstruction algorithm to enable sampling from the left ventricle of the heart. The feasibility of the algorithm and its resistance to cardiac motion are demonstrated in vivo and through numerical simulations. VIF sampling is interleaved with slices dedicated to tumor coverage to yield a fast VIF sampling period (81 ms) that is decoupled from the temporal resolution of tumor data (3.9 s). The algorithm provides results that agree with fully encoded measurements in the slowly varying component of VIF to within a 4% root‐mean‐square signal difference. Analysis of a parametric representation of VIFs measured in a population of mice showed a significant reduction in variations observed within subjects (5%–58% over four parameters; p < 0.05) and a reduction in variations between subjects (19%–62%) when using this technique. Preliminary dynamic measurements in an orthotopic xenograft model of anaplastic thyroid cancer revealed a decrease in the variation of pharmacokinetic parameters between mice by a factor of two. Copyright © 2010 John Wiley & Sons, Ltd.Keywords
This publication has 25 references indexed in Scilit:
- Partial volume effect (PVE) on the arterial input function (AIF) in T1‐weighted perfusion imaging and limitations of the multiplicative rescaling approachMagnetic Resonance in Medicine, 2009
- Comparison of model‐based arterial input functions for dynamic contrast‐enhanced MRI in tumor bearing ratsMagnetic Resonance in Medicine, 2009
- T1 measurement of flowing blood and arterial input function determination for quantitative 3D T1‐weighted DCE‐MRIJournal of Magnetic Resonance Imaging, 2007
- Comparison of a reference region model with direct measurement of an AIF in the analysis of DCE‐MRI dataMagnetic Resonance in Medicine, 2007
- Experimentally‐derived functional form for a population‐averaged high‐temporal‐resolution arterial input function for dynamic contrast‐enhanced MRIMagnetic Resonance in Medicine, 2006
- Quantitative pharmacokinetic analysis of DCE-MRI data without an arterial input function: a reference region modelMagnetic Resonance Imaging, 2005
- Imaging Angiogenesis: Applications and Potential for Drug DevelopmentJNCI Journal of the National Cancer Institute, 2005
- Simultaneous measurement of arterial input function and tumor pharmacokinetics in mice by dynamic contrast enhanced imaging: Effects of transcytolemmal water exchangeMagnetic Resonance in Medicine, 2004
- A method for interleaved acquisition of a vascular input function for dynamic contrast-enhanced MRI in experimental rat tumoursNMR in Biomedicine, 2004