Improving safety in blood transfusion using failure mode and effect analysis
- 4 January 2019
- journal article
- research article
- Published by Wiley in Transfusion
- Vol. 59 (2), 516-523
- https://doi.org/10.1111/trf.15137
Abstract
BACKGROUND One of the medical areas where errors can have more serious consequences is the process of blood transfusion. We used failure mode and effect analysis (FMEA) for evaluating potential failures and improving transfusion safety in a medium‐size urban hospital with a highly complex transfusion service. STUDY DESIGN AND METHODS Each failure mode was evaluated using the likelihood of occurrence, severity of the effect, and probability of detection. The obtained results allowed each failure to be prioritized and decisions to be made in an organized manner to determine solutions. We define measures and indicators that allow the comparison of their results in a longer time period than most of the previous studies. RESULTS The most important failures were those regarding 1) transmitting information about the transfusion request, 2) patient identification, 3) sample identification, 4) cross‐matching ordered tests, 5) transfusing blood components, 6) completing and sending the transfusion control document, and 7) reporting of transfusion reactions. The application of the FMEA methodology allowed implementation of safety measures and monitoring of the measures using indicators, including the mandatory records of the hemovigilance system. There was a 56% improvement in the risk prioritization numbers in the second stage of the FMEA. CONCLUSION FMEA allows for identification of factors that reduce safety in this hospital, analysis of the causes and consequences of these errors, design of corrective measures, and establishment of indicators to monitor their application. The FMEA methodology can help other institutions to identify their own specific vulnerabilities.Keywords
This publication has 11 references indexed in Scilit:
- Preventing blood transfusion failures: FMEA, an effective assessment methodBMC Health Services Research, 2017
- Proactive Risk Assessment of Blood Transfusion Process, in Pediatric Emergency, Using the Health Care Failure Mode and Effects Analysis (HFMEA)Global Journal of Health Science, 2014
- Serious Hazards of Transfusion (SHOT) haemovigilance and progress is improving transfusion safetyBritish Journal of Haematology, 2013
- Failure mode and effect analysis in blood transfusion: a proactive tool to reduce risksTransfusion, 2013
- A Practical Guide to Failure Mode and Effects Analysis in Health Care: Making the Most of the Team and Its MeetingsThe Joint Commission Journal on Quality and Patient Safety, 2010
- Reducing adverse events in blood transfusionBritish Journal of Haematology, 2005
- Engineering for Safety: Use of Failure Mode and Effects Analysis in the LaboratoryLaboratory Medicine, 2005
- Emily Cooley Lecture 2002: transfusion safety in the hospitalTransfusion, 2003
- Failure mode and effect analysis: an application in reducing risk in blood transfusion.The Joint Commission Journal on Quality Improvement, 2002
- Identification and classification of the causes of events in transfusion medicineTransfusion, 1998