Purpose: Accurate segmentation and quantification of liver metastases on CT images are critical to surgery/radiation treatment planning and therapy response assessment. To date, there are no reliable methods to perform such segmentation automatically. In this work, the authors present a method for semiautomatic delineation of liver metastases on contrast‐enhanced volumetric CT images. Methods: The first step is to manually place a seed region‐of‐interest (ROI) in the lesion on an image. This ROI will (1) serve as an internal marker and (2) assist in automatically identifying an external marker. With these two markers, lesion contour on the image can be accurately delineated using traditional watershed transformation. Density information will then be extracted from the segmented 2D lesion and help determine the 3D connected object that is a candidate of the lesion volume. The authors have developed a robust strategy to automatically determine internal and external markers for marker‐controlled watershed segmentation. By manually placing a seed region‐of‐interest in the lesion to be delineated on a reference image, the method can automatically determine dual threshold values to approximately separate the lesion from its surrounding structures and refine the thresholds from the segmented lesion for the accurate segmentation of the lesion volume. This method was applied to 69 liver metastases (1.1–10.3 cm in diameter) from a total of 15 patients. An independent radiologist manually delineated all lesions and the resultant lesion volumes served as the “gold standard” for validation of the method's accuracy. Results: The algorithm received a median overlap, overestimation ratio, and underestimation ratio of 82.3%, 6.0%, and 11.5%, respectively, and a median average boundary distance of 1.2 mm. Conclusions: Preliminary results have shown that volumes of liver metastases on contrast‐enhanced CT images can be accurately estimated by a semiautomatic segmentation method.Keywords
Funding Information
- National Institutes of Health (NIH) (CA140207)
- National Institutes of Health (CA140207)
- National Institutes of Health (CA140207)
This publication has 26 references indexed in Scilit:
- Marker-Controlled Watershed for Lesion Segmentation in MammogramsJournal of Digital Imaging, 2011
- Shape-Constraint Region Growing for Delineation of Hepatic Metastases on Contrast-Enhanced Computed Tomograph ScansInvestigative Radiology, 2006
- Marker‐controlled watershed for lymphoma segmentation in sequential CT imagesMedical Physics, 2006
- Fully Automatic Anatomical, Pathological, and Functional Segmentation from CT Scans for Hepatic SurgeryComputer Aided Surgery, 2001
- A methodology for evaluation of boundary detection algorithms on medical imagesIEEE Transactions on Medical Imaging, 1997
- Evaluation of Selected Two-Dimensional Segmentation Techniques for Computed Tomography Quantitation of Lymph NodesInvestigative Radiology, 1996
- Morphological grayscale reconstruction in image analysis: applications and efficient algorithmsIEEE Transactions on Image Processing, 1993
- Comparing images using the Hausdorff distanceIeee Transactions On Pattern Analysis and Machine Intelligence, 1993
- Morphological segmentationJournal of Visual Communication and Image Representation, 1990
- Liver-Tumor Boundary Detection: Human Observer vs Computer Edge DetectionInvestigative Radiology, 1989