Reliability Analysis for Radiographic Measurement of Limb Length Discrepancy
- 1 January 2007
- journal article
- research article
- Published by Ovid Technologies (Wolters Kluwer Health) in Journal of Pediatric Orthopaedics
- Vol. 27 (1), 46-50
- https://doi.org/10.1097/01.bpo.0000242444.26929.9f
Abstract
Patients with limb length discrepancy (LLD) often have associated angular deformities requiring a standing full-length radiograph of the lower limb in addition to a scanogram. The purpose of our study was to determine the intraobserver and interobserver reliability of measuring LLD with both techniques, using computed radiography. The LLD was measured on 70 supine scanograms and standing anteroposterior radiographs of the lower extremity by 5 blinded observers on 2 separate occasions. Intraclass correlation coefficient (ICC) and mean absolute difference (in millimeters) was calculated to assess intraobserver and interobserver reliability and found to be excellent for both radiographic techniques. Intraobserver ICC and mean absolute difference was 0.975 to 0.995 and 1.5 to 2.6 mm for scanogram and 0.939 to 0.996 and 1.5 to 4.6 mm for the standing radiograph, respectively. Repeated measurements for both radiographic studies were within 5 mm of the first measurement greater than 90% and within 10 mm greater than 95% of times. Interobserver ICC and mean absolute difference was 0.979 and 2.6 mm for scanogram and 0.968 and 3.0 mm for the standing radiograph. The reliability was excellent irrespective of age, sex, and underlying diagnosis other than Blount disease, which had good reliability. A standing anteroposterior radiograph of the lower extremity should be the imaging modality of choice when evaluating patients with limb length inequality who may have angular deformities because it allows a comprehensive evaluation of the extremity and is as reliable as a scanogram for measuring LLD. This approach may decrease the radiation exposure and financial burden involved in assessing patients with unequal limb lengths.Keywords
This publication has 12 references indexed in Scilit:
- Computed Radiographic Measurement of Limb-Length DiscrepancyFull-Length Standing Anteroposterior Radiograph Compared with ScanogramThe Journal of Bone and Joint Surgery (American), 2006
- Reliability and Accuracy of MRI Scanogram in the Evaluation of Limb Length DiscrepancyJournal of Pediatric Orthopaedics, 2005
- Reliability Analysis for Digital Adolescent Idiopathic Scoliosis MeasurementsJournal of Spinal Disorders & Techniques, 2005
- Measurement Variance in Limb Length DiscrepancyJournal of Pediatric Orthopaedics, 2005
- Should full-length standing anteroposterior radiographs replace the scanogram for measurement of limb length discrepancy?Journal of Pediatric Orthopaedics B, 2005
- Fully automatic and reference-marker-free image stitching method for full-spine and full-leg imaging with computed radiographyPublished by SPIE-Intl Soc Optical Eng ,2004
- Measurement of limb length inequality Comparison of clinical methods with orthoradiography in 190 childrenActa Orthopaedica, 1996
- Determination of Leg Length DiscrepancyInvestigative Radiology, 1988
- Computed radiographic imaging: use in low-dose leg length radiographyAmerican Journal of Roentgenology, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986