Bayesian parallel imaging with edge‐preserving priors
Open Access
- 28 December 2006
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 57 (1), 8-21
- https://doi.org/10.1002/mrm.21012
Abstract
Existing parallel MRI methods are limited by a fundamental trade‐off in that suppressing noise introduces aliasing artifacts. Bayesian methods with an appropriately chosen image prior offer a promising alternative; however, previous methods with spatial priors assume that intensities vary smoothly over the entire image, resulting in blurred edges. Here we introduce an edge‐preserving prior (EPP) that instead assumes that intensities are piecewise smooth, and propose a new approach to efficiently compute its Bayesian estimate. The estimation task is formulated as an optimization problem that requires a nonconvex objective function to be minimized in a space with thousands of dimensions. As a result, traditional continuous minimization methods cannot be applied. This optimization task is closely related to some problems in the field of computer vision for which discrete optimization methods have been developed in the last few years. We adapt these algorithms, which are based on graph cuts, to address our optimization problem. The results of several parallel imaging experiments on brain and torso regions performed under challenging conditions with high acceleration factors are shown and compared with the results of conventional sensitivity encoding (SENSE) methods. An empirical analysis indicates that the proposed method visually improves overall quality compared to conventional methods. Magn Reson Med 57:8–21, 2007.Keywords
This publication has 31 references indexed in Scilit:
- Optimizing spatiotemporal sampling for k‐t BLAST and k‐t SENSE: Application to high‐resolution real‐time cardiac steady‐state free precessionMagnetic Resonance in Medicine, 2005
- An experimental comparison of min-cut/max- flow algorithms for energy minimization in visionIeee Transactions On Pattern Analysis and Machine Intelligence, 2004
- What energy functions can be minimized via graph cuts?Ieee Transactions On Pattern Analysis and Machine Intelligence, 2004
- Parallel imaging reconstruction using automatic regularizationMagnetic Resonance in Medicine, 2004
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Recent advances in image reconstruction, coil sensitivity calibration, and coil array design for SMASH and generalized parallel MRIMagnetic Resonance Materials in Physics, Biology and Medicine, 2002
- Fast approximate energy minimization via graph cutsIeee Transactions On Pattern Analysis and Machine Intelligence, 2001
- Advances in sensitivity encoding with arbitrary k‐space trajectoriesMagnetic Resonance in Medicine, 2001
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- A comparison of RIGR and SVD dynamic imaging methodsMagnetic Resonance in Medicine, 1997