ATP bioluminescence assay for evaluating cleaning practices in operating theatres: applicability and limitations
Open Access
- 19 November 2018
- journal article
- research article
- Published by Springer Science and Business Media LLC in BMC Infectious Diseases
- Vol. 18 (1), 1-7
- https://doi.org/10.1186/s12879-018-3505-y
Abstract
Environmental cleaning practice plays an important role in reducing microbial contamination in hospital surfaces and contributes to prevent Healthcare Associated Infections. Adenosine Triphosphate (ATP) bioluminescence assay is a commonly used method for assessing environmental cleanliness on healthcare surfaces. This study tested the feasibility of using ATP-bioluminescence assay for evaluating the efficiency of cleaning procedures in the operating theatre settings, comparing the ATP-bioluminescence test with the traditional culture method. The surfaces of 10 operating rooms of two public hospitals (140 samples in total) were examined “at rest”, in two moments of the same daily session: before the first scheduled operation (Pre), and before the second, after a clean environment was re-established (Post). Surface contamination was assessed using the cultural method to detect Total Viable Counts (TVC36°C) and ATP-bioluminescence assay (RLU). The examined surfaces presented very low TVCs (geometric means: 1.8 CFU/plate; IC95%: 1.6–2.0), always compliant with the relative reference standards. No statistical correlation was found between ATP values and TVCs. However, considering the results in terms of general evaluation of hygienic quality of surfaces, the two methods were consistent in identifying the most contaminated areas (Hospital A > Hospital B; Pre > Post; most contaminated surfaces: scialytic lamp). Furthermore, the ATP mean values showed a progressive increase from surfaces with TVC = 0 to surfaces with TVC > 15 CFU/plate. Although not an alternative to cultural methods, the ATP-bioluminescence-assay can be a useful tool to measure the efficiency of cleaning procedures also in environments with very low microbial counts. Each health facility should identify appropriate reference values, depending on the devices used and on the basis of the analysis of the data collected through spatial and temporal sampling series. By providing a rapid feedback, the ATP-assay helps to increase the awareness of operators and allows immediate action to be taken in critical situations.Keywords
Funding Information
- The study was supported by grants for Local Projects (RFO) provided by the Italian Ministry
This publication has 27 references indexed in Scilit:
- Evaluation of a modified cleaning procedure in the prevention of carbapenem-resistant Acinetobacter baumannii clonal spread in a burn intensive care unit using a high-sensitivity luminometerJournal of Hospital Infection, 2016
- Controlling Hospital-Acquired Infection: Focus on the Role of the Environment and New Technologies for DecontaminationClinical Microbiology Reviews, 2014
- Implementing AORN Recommended Practices for Environmental CleaningAORN Journal, 2014
- Direct feedback with the ATP luminometer as a process improvement tool for terminal cleaning of patient roomsAmerican Journal of Infection Control, 2014
- Evidence that contaminated surfaces contribute to the transmission of hospital pathogens and an overview of strategies to address contaminated surfaces in hospital settingsAmerican Journal of Infection Control, 2013
- Hospital cleaning in the 21st centuryEuropean Journal of Clinical Microbiology & Infectious Diseases, 2011
- Do surface and cleaning chemistries interfere with ATP measurement systems for monitoring patient room hygiene?Journal of Hospital Infection, 2010
- Monitoring the Effectiveness of Hospital Cleaning Practices by Use of an Adenosine Triphosphate Bioluminescence AssayInfection Control & Hospital Epidemiology, 2009
- Is it really clean? An evaluation of the efficacy of four methods for determining hospital cleanlinessJournal of Hospital Infection, 2009
- A modified ATP benchmark for evaluating the cleaning of some hospital environmental surfacesJournal of Hospital Infection, 2008