Sick building syndrome in open‐plan offices
- 21 September 2012
- journal article
- Published by Emerald in Journal of Facilities Management
- Vol. 10 (4), 256-265
- https://doi.org/10.1108/14725961211265729
Abstract
Purpose: The purpose of this article is to present a sick building syndrome (SBS) survey in open‐plan offices. The design factors (indoor plants, workstation partitions, and operable windows) that predict SBS were described for architects and interior designers, and the indoor environmental characteristics (thermal comfort, air quality, noise and lighting) that contribute to SBS symptoms were also investigated.Design/methodology/approach: This study used a standard Building Use Studies (BUS) questionnaire that included sick building syndrome symptoms, environmental satisfaction and perception, and background information about the respondents and their office space. The questionnaire was conducted in 30 offices of building‐related professionals in Hong Kong. There were 469 Chinese office workers that participated.Findings: Indoor plants and operable windows were related to a reduction of SBS symptoms; while workstation partitions did not affect the incidence of SBS symptoms. There were fewer sick building syndrome symptoms reported in the more satisfied respondents.Originality/value: This study highlights a perception‐based solution for facilities design and management.Keywords
This publication has 31 references indexed in Scilit:
- Symptoms prevalence among office workers of a sealed versus a non-sealed building: Associations to indoor air qualityEnvironment International, 2009
- Occupational and Environmental Risk Factors for the Sick Building Syndrome in Modern Offices in Istanbul: A Cross Sectional StudyIndoor and Built Environment, 2007
- Sick Building Syndrome in Mauritius: Are Symptoms Associated with the Office Environment?Indoor and Built Environment, 2000
- The Effect of Indoor Foliage Plants on Health and Discomfort Symptoms among Office WorkersIndoor and Built Environment, 1998
- Sick Building Syndrome: Acoustic AspectsIndoor and Built Environment, 1996
- Individual and Occupational Correlates of the Sick Building SyndromeIndoor Air, 1995
- Office Noise, Satisfaction, and PerformanceEnvironment and Behavior, 1994
- Review : The Sick Building Syndrome: Where Are We in 1992?Indoor Environment, 1992
- Work-related illness in offices: A proposed model of the “sick building syndrome”Environment International, 1989
- The adaptation and control model of user needs: A new direction for housing researchJournal of Environmental Psychology, 1985