Atypical Chest Pain: Coronary, Aortic, and Pulmonary Vasculature Enhancement at Biphasic Single-Injection 64-Section CT Angiography
- 1 May 2007
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 243 (2), 368-376
- https://doi.org/10.1148/radiol.2432060447
Abstract
Purpose: To prospectively evaluate the enhancement of coronary, pulmonary, and thoracic aortic vasculature by using biphasic single-acquisition 64-section computed tomographic (CT) angiography and to prospectively evaluate if differences in right side of the heart and coronary venous enhancement interfere with interpretation of coronary arteries. Materials and Methods: With internal review board approval and HIPAA compliance, 50 patients (16 men, 34 women; mean age, 51.5 years; range, 30–75 years) with atypical chest pain were referred from the emergency department and were imaged with a 64-section CT scanner after premedication with oral atenolol and/or intravenous metoprolol. Thoracic CT angiography with retrospective gating was subsequently performed with a single biphasic injection of 130 mL of iso-osmolar contrast material (100 mL at 5 mL/sec and 30 mL at 3 mL/sec) in caudal-to-cranial acquisition. Coronary, aortic, and pulmonary arterial attenuation values were obtained. Coronary venous and right atrial enhancement were evaluated to assess whether there was interference with coronary artery evaluation. A two-tailed Friedman test was used to evaluate differences among segments within each artery. Results: Mean coronary arterial, pulmonary arterial, and aortic attenuation values were significantly higher than the 250-HU threshold (P < .05). Mean pooled coronary arterial (288.9 HU ± 64.8), pulmonary arterial (316.4 HU ± 79.9), and aortic (329.9 HU ± 63.3) attenuation values were significantly higher than the 250-HU threshold (P < .0001). Coronary venous enhancement did not affect depiction or interpretation of coronary arteries. Right atrial streak artifact focally traversed the right coronary artery in only one study. Conclusion: The aforementioned thoracic CT angiographic protocol provides enhancement of coronary, aortic, and pulmonary vasculature in a single breath hold without interference from right side of the heart streak artifact or coronary venous enhancement. © RSNA, 2007Keywords
This publication has 14 references indexed in Scilit:
- The Indeterminate CT Pulmonary Angiogram: Imaging Characteristics and Patient Clinical OutcomeRadiology, 2005
- Intravenous Contrast Material Administration at 16–Detector Row Helical CT Coronary Angiography: Test Bolus versus Bolus-tracking TechniqueRadiology, 2004
- CT Angiography of Pulmonary Embolism: Diagnostic Criteria and Causes of MisdiagnosisRadioGraphics, 2004
- Uniform Vascular Contrast Enhancement and Reduced Contrast Medium Volume Achieved by Using Exponentially Decelerated Contrast Material Injection MethodRadiology, 2004
- Optimal Contrast Application for Cardiac 4-Detector-Row Computed TomographyInvestigative Radiology, 2003
- Pulmonary Embolism: Optimization of Small Pulmonary Artery Visualization at Multi–Detector Row CTRadiology, 2003
- Multiphasic Injection Method for Uniform Prolonged Vascular Enhancement at CT Angiography: Pharmacokinetic Analysis and Experimental Porcine ModelRadiology, 2000
- The TIMI Risk Score for Unstable Angina/Non–ST Elevation MIJAMA, 2000
- Improved Uniformity of Aortic Enhancement with Customized Contrast Medium Injection Protocols at CT AngiographyRadiology, 2000
- A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart AssociationCirculation, 1975