Technical approaches to the optimisation of CT
- 1 June 2008
- journal article
- review article
- Published by Elsevier BV in Physica Medica-European Journal Of Medical Physics
- Vol. 24 (2), 71-79
- https://doi.org/10.1016/j.ejmp.2008.01.012
Abstract
This paper reviews current technical approaches to the optimisation of CT practice, i.e. approaches to reduce patient dose to the necessary minimum. The most important step towards this goal appears to be the technology of tube current modulation (TCM), which came into practice in the early 2000s and has become the standard approach recently. Anatomy- or attenuation-based TCM allows for a dose reduction between 10 and 60% as compared to scans with constant tube current. Automatic exposure control (AEC) approaches are the next step; based on TCM technology, AEC adapts the tube current both with the rotation angle alpha (alpha-modulation) and along the z-axis (z-modulation) to achieve a pre-selected image quality level at minimal dose. To pre-select the image quality level, i.e. primarily the pixel noise level, tools for simulation are important to investigate the necessary noise levels pro- and retrospectively for given cases and diagnostic tasks. Respective "dose tutor" approaches have become available recently and are presented. The most recent technical innovation which may lead to substantial dose reduction is the investigation of optimal spectra taking the type of contrast and 3D dose distributions into account. A high potential has been shown especially for pediatric CT and for thoracic CT where dose reduction of a factor of 2 and more is possible when using reduced tube voltages.Keywords
This publication has 13 references indexed in Scilit:
- Validation of a Monte Carlo tool for patient-specific dose simulations in multi-slice computed tomographyEuropean Radiology, 2007
- CT Dose Reduction and Dose Management Tools: Overview of Available OptionsRadioGraphics, 2006
- Techniques and Applications of Automatic Tube Current Modulation for CTRadiology, 2004
- Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide surveyEuropean Radiology, 2003
- Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regionsEuropean Radiology, 2000
- Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studiesMedical Physics, 1999
- Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurementsMedical Physics, 1999
- Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadaversEuropean Radiology, 1999
- Das „Smart-Scan”-Verfahren der Spiral-Computertomographie: Eine neue Methode der DosisreduktionRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1996
- Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation.Radiology, 1990