Power Electronic Conditioning Systems for Industrial Photovoltaic Fields: Centralized or String Inverters?
- 1 May 2007
- conference paper
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Abstract
Photovoltaic (PV) plants in Italy are presently subject to a rapid increase due to recent government incentives dedicated to grid connected PV plants. Incentives are given on the basis of the energy actually delivered to the grid, so that it becomes fundamental for the owner to produce as much energy as possible in order to reduce the payback time. In this framework, PV system efficiency plays a fundamental role. This paper focuses on medium and large size PV power systems, for which plant efficiency becomes a key design issue. In particular, the choice between centralized or distributed ("string") architecture is analyzed in terms of plant efficiency, considering the following basic issues: (1) losses in the power electronic conditioning system; (2) losses due to cable dissipation; (3) losses due to possible maximum power point mismatch.Keywords
This publication has 4 references indexed in Scilit:
- A Review of Single-Phase Grid-Connected Inverters for Photovoltaic ModulesIEEE Transactions on Industry Applications, 2005
- Power electronics as efficient interface in dispersed power generation systemsIEEE Transactions on Power Electronics, 2004
- Power inverter topologies for photovoltaic modules-a reviewPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2003
- The 3.3 MW-peak photovoltaic power station at SerrePublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002