New technology enables high precision multislit collimators for microbeam radiation therapy
- 1 July 2009
- journal article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 80 (7), 074301
- https://doi.org/10.1063/1.3170035
Abstract
During the past decade microbeam radiation therapy has evolved from preclinical studies to a stage in which clinical trials can be planned, using spatially fractionated, highly collimated and high intensity beams like those generated at the x-ray ID17 beamline of the European Synchrotron Radiation Facility. The production of such microbeams typically between 25 and 100 microm full width at half maximum (FWHM) values and 100-400 microm center-to-center (c-t-c) spacings requires a multislit collimator either with fixed or adjustable microbeam width. The mechanical regularity of such devices is the most important property required to produce an array of identical microbeams. That ensures treatment reproducibility and reliable use of Monte Carlo-based treatment planning systems. New high precision wire cutting techniques allow the fabrication of these collimators made of tungsten carbide. We present a variable slit width collimator as well as a single slit device with a fixed setting of 50 microm FWHM and 400 microm c-t-c, both able to cover irradiation fields of 50 mm width, deemed to meet clinical requirements. Important improvements have reduced the standard deviation of 5.5 microm to less than 1 microm for a nominal FWHM value of 25 microm. The specifications of both devices, the methods used to measure these characteristics, and the results are presentedThis publication has 13 references indexed in Scilit:
- Microbeam radiation therapy: A Monte Carlo study of the influence of the source, multislit collimator, and beam divergence on microbeamsMedical Physics, 2009
- Synergy of gene-mediated immunoprophylaxis and microbeam radiation therapy for advanced intracerebral rat 9L gliosarcomasJournal of Neuro-Oncology, 2006
- Radiosurgical palliation of aggressive murine SCCVII squamous cell carcinomas using synchrotron-generated X-ray microbeamsThe British Journal of Radiology, 2006
- Applications of synchrotron X-rays to radiotherapyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2005
- Characterization of a tungsten/gas multislit collimator for microbeam radiation therapy at the European Synchrotron Radiation FacilityReview of Scientific Instruments, 2005
- Weanling piglet cerebellum: a surrogate for tolerance to MRT (microbeam radiation therapy) in pediatric neuro-oncologyPublished by SPIE-Intl Soc Optical Eng ,2001
- Microbeam radiation therapyPublished by SPIE-Intl Soc Optical Eng ,1999
- Neuropathology of ablation of rat gliosarcomas and contiguous brain tissues using a microplanar beam of synchrotron-wiggler-generated X raysInternational Journal of Cancer, 1998
- Subacute neuropathological effects of microplanar beams of x-rays from a synchrotron wiggler.Proceedings of the National Academy of Sciences of the United States of America, 1995
- Microbeam radiation therapyMedical Physics, 1992