Diabet. Med. 27, 61–64 (2010) Abstract Aims The reduction of high plantar pressure in diabetic patients with peripheral neuropathy is mandatory for prevention of foot ulcers and amputations. We used a new biofeedback‐based method to reduce the plantar pressure at an at‐risk area of foot in diabetic patients with peripheral neuropathy. Methods Thirteen diabetic patients (age 60.8 ± 12.3 years, body mass index 29.0 ± 5.0 kg/m2) with peripheral neuropathy of the lower limbs were studied. Patients with memory impairment were excluded. The portable in‐shoe foot pressure measurement system (PEDAR®) was used for foot offloading training by biofeedback. The learning procedure consisted in sequences of walking (10 steps), each followed by a subjective estimation of performance and objective feedback. The goal was to achieve three consecutive walking cycles of 10 steps, with a minimum of seven steps inside the range of 40–80% of the baseline peak plantar pressure. The peak plantar pressure was assessed during the learning period and at retention tests. Results A significant difference in peak plantar pressure was recorded between the beginning and the end of the learning period (when the target for plantar pressure was achieved) (262 ± 70 vs. 191 ± 53 kPa; P = 0.002). The statistically significant difference between the beginning of learning and all retention tests persisted, even at the 10‐day follow‐up. Conclusions Terminal augmented feedback training may positively affect motor learning in diabetic patients with peripheral neuropathy and could possibly lead to suitable foot offloading. Additional research is needed to confirm the maintenance of offloading in the long term.Keywords
This publication has 20 references indexed in Scilit:
- Baropodometric information return device for foot unloadingMedical Engineering & Physics, 2009
- Plantar pressure reduction in step-to gait: A biomechanical investigation and clinical feasibility studyClinical Biomechanics, 2008
- A real-time plantar pressure feedback device for foot unloading11No commercial party having a direct financial interest in the results of the research supporting this article has or will confer a benefit upon the authors(s) or upon any organization with which the author(s) is/are associated.Archives Of Physical Medicine and Rehabilitation, 2004
- Pressure and the diabetic foot: clinical science and offloading techniquesThe American Journal of Surgery, 2004
- Reducing Dynamic Foot Pressures in High-Risk Diabetic Subjects With Foot Ulcerations: A comparison of treatmentsDiabetes Care, 1996
- Sensate and insensate in-shoe plantar pressuresArchives Of Physical Medicine and Rehabilitation, 1993
- Peripheral neuropathy and the diabetic footThe Foot, 1992
- Pathways to Diabetic Limb Amputation: Basis for PreventionDiabetes Care, 1990
- Patient education as the basis for diabetes care in clinical practice and researchDiabetologia, 1985
- Reduction of Abnormal Foot Pressures in Diabetic Neuropathy Using a New Polymer Insole MaterialDiabetes Care, 1984