Randomized Trial on the Influence of the Length of Two Insulin Pen Needles on Glycemic Control and Patient Preference in Obese Patients with Diabetes
- 1 July 2011
- journal article
- research article
- Published by Mary Ann Liebert Inc in Diabetes Technology & Therapeutics
- Vol. 13 (7), 737-741
- https://doi.org/10.1089/dia.2011.0010
Abstract
Objective: This study determined the influence of needle length for insulin administration on metabolic control and patient preference in obese patients with diabetes mellitus. Methods: In this multicenter, open-label crossover study, insulin pen needles of two different lengths (5 mm and 8 mm) were compared. A total of 130 insulin-treated type 1 and type 2 diabetes patients with a body mass index ≥30 kg/m2 were randomized, and 126 patients completed the study. Patients started using the 5-mm needle for 3 months, after which they switched to injecting insulin with the 8-mm needle for another 3 months, or vice versa. Hemoglobin A1c (A1C), fructosamine, and 1,5-anhydroglucitol were measured, and self-reported side effects and patient preference were recorded. Results: No within-group changes were observed with respect to A1C, serum fructosamine, 1,5-anhydroglucitol, hypoglycemic events, bruising, and pain. When data of all 126 subjects were pooled, there was a small, but significant, difference between needle lengths (5-mm, A1C 7.47 ± 0.9%; 8-mm, 7.59 ± 1.0%; P = 0.02). Patients reported less bleeding with the 5-mm needle (P = 0.04) and less insulin leakage from the skin with the 8-mm needle (P = 0.01). There were no significant differences in patient preference, with 46% of the patients preferring the 5-mm needle, 41% the 8-mm needle, and 13% not preferring a particular needle length. Conclusions: A 5-mm needle is similar to an 8-mm needle in obese patients with diabetes with respect to metabolic control, injection-related complaints, or patient preference and can be used safely.Keywords
This publication has 18 references indexed in Scilit:
- New injection recommendations for patients with diabetesDiabetes & Metabolism, 2010
- Results and analysis of the 2008–2009 Insulin Injection Technique Questionnaire surveyJournal of Diabetes, 2010
- Comparative glycemic control, safety and patient ratings for a new 4 mm × 32G insulin pen needle in adults with diabetesCurrent Medical Research and Opinion, 2010
- Association of 1,5-Anhydroglucitol and 2-h Postprandial Blood Glucose in Type 2 Diabetic PatientsDiabetes Care, 2008
- Influence of needle size for subcutaneous insulin administration on metabolic control and patient acceptanceEuropean Diabetes Nursing, 2007
- Pain following controlled cutaneous insertion of needles with different diametersSomatosensory & Motor Research, 2006
- Insulin AdministrationDiabetes Care, 2004
- A pan‐European epidemiologic study of insulin injection technique in patients with diabetesPractical Diabetes International, 2002
- Insulin Injection Site Tissue Depths and Localization of a Simulated Insulin Bolus Using a Novel Air Contrast Ultrasonographic Technique in Insulin Treated Diabetic SubjectsDiabetic Medicine, 1992
- Different Absorption of Isophane (NPH) Insulin from Subcutaneous and Intramuscular Sites Suggests a Need to Reassess Recommended Insulin Injection TechniqueDiabetic Medicine, 1990