Infection after pacemaker implantation: infection rates and risk factors associated with infection in a population-based cohort study of 46299 consecutive patients
Top Cited Papers
Open Access
- 20 January 2011
- journal article
- research article
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 32 (8), 991-998
- https://doi.org/10.1093/eurheartj/ehq497
Abstract
Infection is a serious complication of pacemaker (PM) systems. Although the rate of infection has been debated, the figures are largely unknown. We therefore studied the incidence of PM infection and its associated risk factors in the Danish population. Since 1982, all PM implantation and removal procedures performed in Denmark have been prospectively recorded in the Danish Pacemaker Register. All patients (n = 46299) who underwent implantation between 1982 and 2007 were included. The total length of surveillance was 236 888 PM-years. The incidence of infection was calculated according to the total number of PM-years. The incidence of surgical site infection (≤365 days after PM implantation) was compared with later infection in first implant and replacement procedures. Multiple-record and multiple-event-per-subject proportional hazards analyses were used to identify the independent risk factors of PM infection. Surgical site infection occurred in 192 cases after first implantation (incidence rate 4.82/1000 PM-years), and in 133 cases after replacement (12.12/1000 PM-years). Infections occurring more than 365 days after the first implantation occurred in 153 cases (1.02/1000 PM-years), and in 118 cases after replacement (3.26/1000 PM-years). Independent factors associated with an increased risk of PM infection were a greater number of PM operations (including replacements), male sex, younger age, implantation during the earliest part of the study period, and absence of antibiotics (P< 0.001). The overall risk of infection after PM implantation was low. A greater number of operations augmented the risk of infection. This should be taken into account when considering revisions of PM systems.Keywords
This publication has 31 references indexed in Scilit:
- Risk factors and time delay associated with cardiac device infections: Leiden device registryHeart, 2009
- The World Survey of Cardiac Pacingand Cardioverter‐Defibrillators: Calendar Year 2005 An International Cardiac Pacing andElectrophysiology Society (ICPES) projectPacing and Clinical Electrophysiology, 2008
- Pacemaker Infections: A 10-Year ExperienceNew Zealand Medical Journal, 2007
- Permanent Pacemaker and Implantable Cardioverter Defibrillator InfectionArchives of Internal Medicine, 2007
- Rising Rates of Cardiac Rhythm Management Device Infections in the United States: 1996 through 2003Journal of the American College of Cardiology, 2006
- Long term complications in single and dual chamber pacing are influenced by surgical experience and patient morbidityHeart, 2005
- Local symptoms at the site of pacemaker implantation indicate latent systemic infectionHeart, 2004
- Increasing rates of cardiac device infections among medicare beneficiaries: 1990–1999American Heart Journal, 2004
- Staphylococcus aureus Bacteremia in Patients With Permanent Pacemakers or Implantable Cardioverter-Defibrillators Circulation, 2001
- Guideline for Prevention of Surgical Site Infection, 1999Infection Control & Hospital Epidemiology, 1999