Modeling and Simulation of Turbulent Flows through a Solar Air Heater Having Square-Sectioned Transverse Rib Roughness on the Absorber Plate
Open Access
- 9 October 2013
- journal article
- research article
- Published by Hindawi Limited in The Scientific World Journal
- Vol. 2013, 1-12
- https://doi.org/10.1155/2013/827131
Abstract
Solar air heater is a type of heat exchanger which transforms solar radiation into heat energy. The thermal performance of conventional solar air heater has been found to be poor because of the low convective heat transfer coefficient from the absorber plate to the air. Use of artificial roughness on a surface is an effective technique to enhance the rate of heat transfer. A CFD-based investigation of turbulent flow through a solar air heater roughened with square-sectioned transverse rib roughness has been performed. Three different values of rib-pitch () and rib-height () have been taken such that the relative roughness pitch () remains constant. The relative roughness height,, varies from 0.021 to 0.06, and the Reynolds number, Re, varies from 3800 to 18,000. The results predicted by CFD show that the average heat transfer, average flow friction, and thermohydraulic performance parameter are strongly dependent on the relative roughness height. A maximum value of thermohydraulic performance parameter has been found to be 1.8 for the range of parameters investigated. Comparisons with previously published work have been performed and found to be in excellent agreement.
Keywords
This publication has 13 references indexed in Scilit:
- Numerical investigation of flow through an artificially roughened solar air heaterInternational Journal of Ambient Energy, 2013
- A CFD (computational fluid dynamics) based heat transfer and fluid flow analysis of a solar air heater provided with circular transverse wire rib roughness on the absorber plateEnergy, 2013
- Heat transfer and fluid flow analysis of solar air heater: A review of CFD approachRenewable and Sustainable Energy Reviews, 2013
- Heat and fluid flow characteristics of roughened solar air heater ducts – A reviewRenewable Energy, 2012
- Analysis of fluid flow and heat transfer in a rib grit roughened surface solar air heater using CFDSolar Energy, 2010
- A review on methodology of artificial roughness used in duct of solar air heatersEnergy, 2010
- Performance of artificially roughened solar air heaters—A reviewRenewable and Sustainable Energy Reviews, 2009
- CFD based performance analysis of a solar air heater duct provided with artificial roughnessRenewable Energy, 2009
- Analysis of heat transfer augmentation and flow characteristics due to rib roughness over absorber plate of a solar air heaterRenewable Energy, 2006
- Thermohydraulic performance of solar air heaters with roughened absorber platesSolar Energy, 1997